Food & Pharma FDA-compatible vacuum accessories · Silicone & Colour Line

RAKE – Food & Pharma

FDA 21 CFR 177.2600 BfR Recommendation XV Wacker R 4001 80 GMP-compatible −60°C to +200°C (silicone) Ø38 – Ø70 mm
RAKE comb nozzle in transparent FDA-compatible silicone for food and pharma environments – Ø38 to Ø70 mm
Also available in colour-coded FDA NBR Colour Line · 5 colours · FDA 21 CFR 177.2600

Used together with

RAKE comb nozzle for precise broad-surface extraction of food waste, crumbs, powder and granules in production lines. Available in transparent silicone with documented compliance with FDA 21 CFR 177.2600 and BfR Recommendation XV — and in colour-coded FDA NBR rubber for colour-managed hygiene systems (Colour Line).

Silicone – White Line

Transparent silicone – FDA & BfR compliant

Material
Silicone
Wacker R 4001 80
FDA
21 CFR 177.2600
Food contact
BfR
Recommendation XV
Silicone (DE)
Temperature
−60 / +200°C
Autoclavable
Product codeØ mmMaterialColour
PV238S(X)38Silicone, Wacker R 4001 80Transparent
PV240S(X)40Silicone, Wacker R 4001 80Transparent
PV244S(X)44Silicone, Wacker R 4001 80Transparent
PV200S(X)50Silicone, Wacker R 4001 80Transparent
PV270S(X)70Silicone, Wacker R 4001 80Transparent

Colour versions: replace (X) with colour letter — e.g. PV238SB (blue), PV238SR (red), PV238SV (green), PV244SG (yellow), PV244SW (white). Colours on request.

Applications

  • Collection of food waste, crumbs, powder and granules in production lines
  • Extraction of chemical dust and particle residues in pharma environments
  • Cleaning of production equipment and bench surfaces in cleanroom-adjacent zones
  • Flour and confectionery industries, dairy, cosmetics and chemical manufacturing
Compliance information: The silicone compound Wacker Chemie R 4001 80 complies with FDA 21 CFR 177.2600 (USA) and BfR Recommendation XV “Silicone” (Germany) for the polymers and ingredients in the material. It is the manufacturer’s responsibility to ensure that the moulding and finishing process meets these standards, and the end user’s responsibility to verify material compatibility with the specific intended application.
Colour Line – FDA NBR

Colour-coded FDA NBR rubber – for hygiene colour management systems

Material
FDA NBR
Oil-resistant rubber
FDA
21 CFR 177.2600
On request – F suffix
Antistatic
No
Standard version
Temperature
−20 / +120°C
Operating range

How to build the part number

PV + diameter + colour + F

Example: Ø40 mm, blue, FDA = PV240BF  ·  Ø38 mm, red, FDA = PV238RF

B = Blue R = Red G = Yellow V = Green W = White
Ø mm Blue (B) Red (R) Yellow · Green · White
38PV238BFPV238RFPV238GF / PV238VF / PV238WF – on request
40PV240BFPV240RFPV240GF / PV240VF / PV240WF – on request
44PV244BFPV244RFPV244GF / PV244VF / PV244WF – on request
50PV200BFPV200RFPV200GF / PV200VF / PV200WF – on request
70PV270BFPV270RFPV270GF / PV270VF / PV270WF – on request

F = FDA rubber per 21 CFR 177.2600. All colours available — contact us for lead time.

Colour coding and hygiene

The Colour Line concept enables systematic colour coding of vacuum accessories in food and pharma environments, where visual segregation of equipment forms part of internal hygiene procedures and GMP requirements. Colour coding reduces the risk of cross-contamination by assigning specific colours to separate process zones, allergen statuses or product types:

  • Blue — allergen-free zones or dry products
  • Red — meat processing or controlled process zones
  • Green / yellow / white — additional colours adapted to internal colour coding systems
Please note: The standard Colour Line is manufactured in oil-resistant NBR rubber without FDA compliance. FDA-compatible versions carry the suffix F and must be specified at the time of ordering. It is the end user’s responsibility to verify the material’s suitability for the specific application.

Frequently asked questions

The silicone version (White Line) is compliant with FDA 21 CFR 177.2600 and BfR Recommendation XV in its standard form, withstands −60°C to +200°C and can be autoclaved. Colour Line is manufactured in oil-resistant NBR rubber and is available in an FDA-compatible (F) version on request, with an operating range of −20°C to +120°C. Colour Line is primarily intended for colour-coded hygiene management systems.
Yes. The silicone material Wacker Chemie R 4001 80 has an operating temperature range of −60°C to +200°C, making autoclaving possible as part of a hygiene routine. It is the user’s responsibility to verify that the rest of the tube system and accessories are also rated for the autoclaving temperature.
FDA 21 CFR 177.2600 is the US Food and Drug Administration’s regulation for rubber materials approved for repeated contact with food. BfR Recommendation XV is the equivalent German requirement for silicone materials in food contact. For the silicone version, compliance is documented for the compound Wacker Chemie R 4001 80. The end user is responsible for verifying suitability for the specific intended use.
The characteristic teeth distribute the airflow evenly across the opening width and prevent the nozzle from adhering to the surface. This provides even collection of crumbs, granules and fine powder from both hard production surfaces and flexible surfaces.
The part number is built as PV + diameter + colour letter + F. Example: Ø38 mm in green FDA version = PV238VF. Contact us with the required diameter, colour and quantity.
Yes — RAKE is also available in antistatic MM019NN NBR compound for use in ATEX Zone 21 and Zone 22, with documented volume resistivity of 1.1 Ω·m (CERISIE, ISO 1853:2011). See the ATEX product page for details.

Need advice on food and pharma accessories?

Particulair helps you select the right material variant, diameter and colour coding for your specific environment.