Home / Shop /Cleaning in high-risk areas (Zone 21) / Delfin MTL 451 Inert Z21

Delfin MTL 451 Inert Z21

Compact Zone 21 certified vacuum cleaner with liquid bath for explosive dust

The Delfin MTL 451 INERT Z21 is a mobile industrial vacuum cleaner designed for the safe collection of gunpowder and metal dust in the most hazardous areas of indoor shooting ranges. With Notified Body certification (IECEx/ATEX 1/2D) and H14 HEPA filtration, it effectively neutralizes reactive dust in full compliance with the strictest EU ATEX and occupational health requirements.

Certified safety – ATEX Zone 21

The MTL 451 INERT Z21 is approved for use in Zone 21 (II 1/2D) and operates in an internal Zone 20 environment. Its liquid bath technology neutralizes dust directly in inert fluid, eliminating the risk of sparks, heat buildup, or static electricity. Certification by Notified Body 0081 provides documented assurance of safety for explosive dust.

Why the liquid bath is essential

Experience from incidents in both Europe and the USA shows that standard ATEX vacuums are not sufficient in Zone 21 when only using dry collection. With the MTL 451’s liquid bath, dust is immediately isolated and neutralized, breaking the ignition chain directly inside the collection tank.

Complete protection and user-friendliness

The MTL 451 INERT Z21 combines H14 HEPA filtration (99.995% retention at MPPS according to EN 1822) with full ESD grounding, manual filter cleaning, and a compact design. Its 45-liter AISI304 stainless steel tank makes disposal and handling simple, while the robust construction ensures durability for intensive use in shooting ranges and technical rooms.

Application areas

ATEX Zone 21 (with liquid bath):

  • Bullet traps and backstops with powder and metal dust
  • Emptying of containers and filters with unknown or reactive dust
  • Reloading areas and powder spills
  • Small technical rooms and shafts with accumulated dust
  • Smaller shooting houses and container ranges

Supplementary HEPA H14 protection:

  • Changing rooms and exit zones against lead contamination
  • Corridors and storage areas
  • Workshops and maintenance areas

Neutralizing the risk

Contact us for advice on Zone 21 classification and liquid bath technology – we will help you choose the documented solution for the most critical areas of your shooting range.

Contact us

Technical data for Delfin MTL 451 Inert Z21

Model NameMTL 451 INERT Z21
Use ZoneZone 20 (internal) / Zone 21 (external)
MarkingII 1/2D Ex h tb IIIC T80°C (int) / T95°C (ext) Da/Db
EX CategoryCE EX 21 1/2D
Voltage115/230 V – 50/60 Hz – 1~
Power1.1 kW
Current Draw8 A
Max Vacuum Pressure2250 mmH₂O
Max Airflow215 m³/h
Suction Inlet50 mm
Inert Liquid Capacity10 liters
Inert Liquid Capacity + Collected Material15 liters
Noise Level74 dB(A)
Dimensions61 × 66 × 133 cm
Weight52 kg
Primary FilterStar / pocket filter
Filter Surface and Diameter20,000 cm² – Ø 420 mm
Filter Media and ClassPolyester ANT M
Air Load on Filter108 m³/m²/h
Cleaning SystemManual
Absolute Filter Class HIncluded
Absolute Filter Surface11,000 cm²
Filtration ClassH14 – 99.995% at MPPS according to EN 1822

Scroll to Top