Depureco DF22 DEX 3/3G
ATEX dust collector for gas Zone 2 – internal and external
Depureco DF22 DEX 3/3G is an ATEX dust collector designed as a mobile filter unit for the collection of airborne material in environments with potentially explosive gas atmospheres. The unit is developed for point extraction and process extraction where ATEX-approved extraction is required in gas Zone 2.
The dust collector is marked II 3/3G Ex h IIB T3 Gc/Gc and is designed as a “Dry Type” dust collector in accordance with EN 17348. The ATEX category 3/3G means that the unit is classified for gas Zone 2 both inside the machine and in the surrounding environment.
Application
DF22 DEX 3/3G is used for extraction at process equipment, filling stations and work areas where explosive gas mixtures may occur. The mobile filter unit can be used with direct hose connection or combined with an extraction arm for flexible point extraction in ATEX-classified gas environments.
Product images show applications in industrial environments where controlled extraction is required to maintain safe operation in gas Zone 2.
Key features
- ATEX marking: II 3/3G Ex h IIB T3 Gc/Gc
- Suitable for gas Zone 2 – internal and external
- Dry Type dust collector according to EN 17348
- 3G ATEX-certified electric fan
- Motor power: 2.2 kW, 400 V / 50–60 Hz
- Antistatic polyester star filter, dust class M
- Manual filter cleaning
- AISI 304 stainless steel collection bin, 65 litres
Technical design
The suction unit consists of an ATEX-certified electric fan that generates the required airflow through the filtration system. The construction is suitable for operation in gas Zone 2, both internally and externally.
The filter unit is built around an antistatic polyester star filter with manual filter cleaning. Collected material is discharged into an AISI 304 stainless steel bin mounted on a mobile chassis.
Safety and certification
- ATEX marking: II 3/3G Ex h IIB T3 Gc/Gc
- Gas Zone 2 – internal and external
- Compliance with EN 17348 (Dry Type dust collector)
- Antistatic filter media and proper grounding
Technical note
The ATEX category 3/3G is used in applications where explosive gas atmospheres may occur occasionally. The classification covers both the internal part of the machine and the surrounding environment.
Correct selection of ATEX-approved accessories and proper grounding are essential for overall safety.
Relevant articles
Technical specifications
| ATEX marking | II 3/3G Ex h IIB T3 Gc/Gc |
| ATEX zone | Gas Zone 2 (internal and external) |
| Motor / fan | 3G ATEX-certified electric fan |
| Motor power | 2.2 kW |
| Voltage / frequency | 400 V / 50–60 Hz |
| IP / insulation class | IP55 / F |
| Maximum vacuum | 350 mm H₂O |
| Airflow | 800 m³/h |
| Filter type | Star filter |
| Filter cleaning | Manual |
| Collection bin | 65 litres, AISI 304 stainless steel |
| Noise level | 73 dB(A) |