Home / Shop /ATEX Combined Zones (Gas/Dust) / Tiger-Vac CD-35L (DT) EX (MRP) EXTENDED 2GD

Tiger-Vac CD-35L (DT) EX (MRP) EXTENDED 2GD

ATEX Zone 1/21 industrial vacuum cleaner with Reverse Purge filter system

The Tiger-Vac CD-35L (DT) EX (MRP) EXTENDED CAT. 2GD Z1/21 is an ATEX and IECEx certified industrial vacuum cleaner designed for the safe recovery of combustible dusts and flammable gases in hazardous areas. The unit is classified II 1/2GD with internal Zone 0/20 and external Zone 1/21 protection, making it suitable for both explosive gas atmospheres and conductive dust (Dust Group IIIC).

Reverse Purge filter system (MRP)

This model uses the Tiger-Vac Manual Reverse Purge (MRP) system, where a strong reverse airflow pulse cleans the filter cartridge without manual shaking. The primary cartridge filter is a static dissipative aluminized spun-bond media with high mechanical strength, low pressure drop and excellent performance on fine dry dust.

EX-rated construction for gas and dust zones

The external protection features Ex db h IIB T4 Gb for safe use in Zone 1 gas environments, while the internal chamber is certified for Zone 0 (gas) and Zone 20 (dust). This provides one of the highest combined ATEX/IECEx classifications available for industrial vacuum systems.

Continuous-duty motor and stainless steel design

The CD-35L EXTENDED is built with a 3-phase TEFC explosion-proof motor designed for continuous operation. The vacuum body and 35 L detachable tank (DT) are made from AISI 304 stainless steel, mounted on a robust powder-coated steel frame. The system is fully ESD-safe with total system resistance below 10 ohms.

High-efficiency HEPA/ULPA filtration options

For applications requiring the highest filtration performance, optional downstream HEPA H14 (99.995% @ 0.3 µm) or ULPA U15 (99.9995% @ 0.12 µm) modules are available. All filters are aerosol leak tested according to EN 1822 and IEST RP standards.

Need assistance with ATEX Zone 1/21?

We provide guidance on ATEX category selection, filtration and the safe handling of combustible or conductive dusts.

Contact us

FAQ

Which ATEX zones is the vacuum certified for?
External: Zone 1 (gas) + Zone 21 (dust).
Internal: Zone 0 (gas) + Zone 20 (dust).

What dust types can it handle?
Dust Groups IIIA, IIIB and IIIC, including highly conductive metal dust (aluminium, magnesium).

Is it suitable for gas environments?
Yes – it carries Ex db h IIB T4 Gb (external) and Ex h IIC T6 Ga (internal).

Is HEPA filtration available?
Yes – HEPA H14 and ULPA U15 can be added as optional modules.

Related links

Technical specifications – Tiger-Vac CD-35L (DT) EX (MRP) EXTENDED CAT. 2GD Z1/21

All values provided by the manufacturer. Specifications may change without notice.
Model nameCD-35L (DT) EX (MRP) EXTENDED 2GD Z1/21
Part no.112529B1
TypeElectric, explosion-proof
Motor3-phase TEFC EX – Continuous Duty
Voltage400 V
Frequency50 Hz
Phase3~
Power4.0 kW (4000 W)
Airflow306 m³/h
Vacuum3380 mm H₂O
VRV setting2030 mm H₂O
Sound level72 dB(A)
Suction inletØ50 mm
Recovery tank35 L (DT – Detachable Tank)
Filter cleaningManual Reverse Purge (MRP)
Primary filterAluminized spun-bond cartridge (SD)
Secondary filterSafety Filter + Filter Cage
HEPA/ULPA optionsHEPA H14 / ULPA U15
MaterialsAISI 304 stainless steel + powder-coated steel frame
IP ratingIP65 motor and switch box
ESD levelTotal system resistance < 10 Ω
Length102 cm
Width61 cm
Height142 cm
Weight125 kg
Power cord10 m