Tiger-Vac CD-EUR-36L EX DT (MFS) ULPA WITH SS CART 1/2GD
ATEX 1/2GD industrial vacuum cleaner with ULPA U15 filtration and stainless steel cart for Zone 1, 2, 21 and 22
The Tiger-Vac CD/EUR-36L EX DT (MFS) ULPA WITH SS CART is a fully ATEX- and IECEx-certified industrial vacuum system in AISI 304 stainless steel, designed for the safe recovery of combustible and conductive dusts in Gas Zones 1–2 and Dust Zones 21–22. Compared to the HEPA version, this model features a standard ULPA U15 final filter (99.9995% at 0.18 µm), making it compatible with cleanroom environments down to ISO Class 4 and particularly suitable for pharmaceutical, biotech and food processing applications.
- ATEX marking: II 1/2GD – External: Ex db h IIB T4 Gb / Ex h tb IIIC T135°C Db IP65 – Internal: Ex h IIC T6 Ga / Ex h IIIC T50°C Da.
- ULPA U15 final filter (included) – 99.9995% efficiency at 0.18 µm, tested according to EN 1822 (MPPS).
- Upstream HEPA H14 filter (included) – 99.995% at 0.3 µm – ensures maximum operator protection and cleanroom compliance.
- Full AISI 304 stainless steel construction – cart, filter chamber and recovery tank.
- Manual Filter Shaker (MFS) for effective on-demand cleaning of the main filter during operation.
- ESD-safe system with overall resistivity below 10 ohms – engineered for conductive and metal dust recovery.
Filtration system and technical design
The unit is equipped with a static dissipative PTFE-laminated star-shaped main filter with a total filter area of 8,584 cm², placed inside a removable filter chamber for easy access and service. The 212 m³/h airflow combined with a vacuum level of up to 2,540 mm H₂O provides efficient recovery of fine, hazardous and potentially explosive dust. The ULPA U15 final filter ensures extremely high retention of ultrafine particles, making the vacuum suitable for ISO Class 4 (former Class 10) cleanrooms.
The vacuum uses a Carriage with Suspended Motor Top (CSMT) design to reduce vibration and optimise airflow. The 36 L detachable stainless-steel recovery tank (DT) allows quick and dust-free disposal, and optional static dissipative poly liners are available for controlled waste handling.
Safety, certifications and ESD control
- ATEX 3rd-party certified by LCIE (0081) according to Directive 2014/34/EU.
- IECEx certified: IECEx LCI 10.0040X.
- Designed in accordance with EN 17348 for combustible dust collection.
- ESD-protected system: resistivity below 10 ohms, static dissipative wheels and controlled contact surfaces.
- Temperature range: -5 °C to +37 °C.
- Fully suitable for conductive metal dusts (Dust Group IIIC).
Applications and industries
The Tiger-Vac CD/EUR-36L EX DT (MFS) ULPA WITH SS CART is designed for environments requiring extremely high air purity, particle control and explosion protection, including pharmaceuticals, biotechnology, food production, cleanrooms, chemical processing, metal powders, additive manufacturing (3D printing), fine chemical production and general ATEX-classified industries. Its tall vertical configuration and stainless-steel cart make it ideal for hygienic installations with limited floor space.
Need assistance with ULPA-classified ATEX vacuum systems?
Contact us for guidance on ATEX/IECEx documentation, cleanroom-compatible vacuum systems and ESD-safe configurations.
FAQ
What is the difference between this model and the HEPA version?
The ULPA model uses a U15 filter as standard (99.9995%), enabling higher particle retention and suitability for ISO Class 4 cleanrooms and critical pharmaceutical processes.
Can this vacuum be used for conductive metal powders?
Yes. The system is ESD safe with resistivity below 10 ohms, and the construction is certified for Dust Group IIIC. Explosion-proof accessories are recommended.
Which filters are included?
The unit includes both an upstream HEPA H14 filter and a downstream ULPA U15 filter, each aerosol leak tested before shipment.
Is the ULPA model suitable for pharmaceutical environments?
Yes. The full AISI 304 stainless-steel construction and U15 filtration make it ideal for FDA, GMP and cleanroom applications.
Are multiple voltage options available?
Yes – both 230 V (single-phase) and 400 V (three-phase) versions are available, with identical performance values.
Related links
Technical specifications – Tiger-Vac CD/EUR-36L EX DT (MFS) ULPA WITH SS CART
| Specification | 230 V – Single-phase (112150B3-SS) | 400 V – Three-phase (112150B1-SS) |
|---|---|---|
| ATEX marking | II 1/2GD – Ex db h IIB T4 Gb / Ex h tb IIIC T135°C Db IP65 – Internal: Ex h IIC T6 Ga / Ex h IIIC T50°C Da | |
| Zone classification | Gas Zone 1–2 / Dust Zone 21–22 (EN 17348 DT) | |
| Temperature range | -5 °C to +37 °C | |
| Voltage | 230 V | 400 V |
| Frequency | 50 Hz | 50 Hz |
| Phase | Single-phase | Three-phase |
| Power (W/KW) | 1,500 W / 1.5 kW | 2,200 W / 2.2 kW |
| Current draw | 12.3 A | 4.8 A |
| Airflow | 212 m³/h | |
| Vacuum pressure | 2,540 mm H₂O (VRV: 1,780 mm H₂O) | |
| Sound level with muffler | 72 dB(A) | |
| Suction inlet | Ø50 mm | |
| Filter cleaning | Manual Filter Shaker (MFS) | |
| Main filter | PTFE static dissipative star filter – 8,584 cm² | |
| Upstream HEPA | HEPA H14 – 99.995% at 0.3 µm (included) | |
| Final filter | ULPA U15 – 99.9995% at 0.18 µm (included) | |
| Recovery tank | 36 L detachable stainless-steel tank | |
| Materials | AISI 304 stainless steel (cart, tank and filter chamber) | |
| ESD performance | System resistivity < 10 ohms – ESD-safe design | |
| Dimensions (L × W × H) | 76 × 61 × 191 cm | 78 × 61 × 191 cm |
| Weight | 113 kg | |
| Cord length | 10 m | |
| Accessories | Stainless-steel muffler, ESD grounding multimeter, optional static dissipative accessories in Ø38/Ø50 mm | |