Home / Shop /ATEX Combined Zones (Gas/Dust) / Tiger-Vac CD/EUR-50L EX DT (MRP) 1/2GD

Tiger-Vac CD/EUR-50L EX DT (MRP) 1/2GD

ATEX 1/2GD industrial vacuum for Zones 1, 2, 21 and 22 with internal Zone 20 protection

The Tiger-Vac CD/EUR-50L EX DT (MRP) 1/2GD is a fully ATEX- and IECEx-certified industrial vacuum cleaner designed for the safe recovery of combustible, conductive and metallic dusts as well as flammable gases and vapours. Classified as II 1/2GD, it provides full internal Zone 20 protection (1D/1G) and external Zone 1/21 and Zone 2/22 protection (2GD). The system includes an efficient MRP – Manual Reverse Purge filter cleaning mechanism, a static dissipative reverse-purge cartridge, a U15 ULPA final filter and a robust SS304 stainless-steel construction.

  • ATEX category II 1/2GD – internal Zone 20/0 and external Zone 1/21/22.
  • IECEx certified (IECEx LCI 10.0040X).
  • U15 ULPA final filter included: 99.999% @ 0.12 μm.
  • MRP filter cleaning – manual reverse purge without compressed air.
  • Static-dissipative filter cartridge and components (<10 Ω).
  • 4.0 kW TEFC explosion-proof/dust ignition-proof motor for continuous duty.
  • 50 L SS304 detachable recovery tank (DT), compatible with poly liners.
  • IP65 dust-tight housing and ISO Class 4 cleanroom compatibility.

Certification & safety

According to ATEX certificate LCIE 03 ATEX 6295 X, the vacuum is certified for use in explosive atmospheres involving both gases and dusts. Internal classification is Ex h IIC T6 Ga and Ex h IIIC T50°C Da, providing the highest protection inside the filter chamber and tank. External classification is Ex db h IIB T4 Gb and Ex h tb IIIC T135°C Db IP65, allowing installation in Zone 1, Zone 2, Zone 21 and Zone 22.

  • Less than 10 Ω resistivity – full ESD protection.
  • ULPA leak-tested according to EN 1822 and factory aerosol testing.
  • Approved for both GAS (G) and DUST (D) hazardous areas.

Construction & performance

The MRP system uses an internal aluminised, static-dissipative spunbond cartridge that is cleaned manually via a reverse purge action, without the need for compressed air. Combined with a stainless-steel 304 construction and ULPA U15 filtration, the vacuum is ideal for high-risk environments where explosive gases and dusts may coexist.

  • Airflow: 299 m³/h
  • Vacuum: 3,380 mm H₂O
  • VRV setting: 2,030 mm H₂O
  • Sound level: 75 dB(A)
  • Suction inlet: Ø63.5 mm

Applications

This 1/2GD model is designed for environments where explosive gas and dust atmospheres may be present simultaneously, and where maximum internal protection combined with certified external zone compliance is required:

  • Pharma & biotech: ULPA U15, SS304, ISO Class 4.
  • Additive manufacturing: conductive and metallic powders.
  • Food production: flour, sugar, starch and fine powders.
  • Chemical industry: combustible vapours + combustible dust.
  • Process industries: suitable for Zone 1/2/21/22.

Technical note

In ATEX 1/2GD applications, correct bonding and grounding of hoses, tools, piping and operator workflow is mandatory according to TRGS 727, EN 1127-1 and NFPA 77. Although the vacuum is static-dissipative (<10 Ω), safe operation depends on proper grounding of the entire installation and the use of EX-rated accessories.

Need help selecting ATEX equipment for Zones 1/2/21/22?

We provide guidance on ATEX documentation, zone classification and safe recovery of combustible dusts and gases.

Contact us

FAQ

What does 1/2GD mean?
Internal Zone 20 (1D) + internal Zone 0 (1G) + external Zones 1/21/22 (2GD).

Is it suitable for both gas and dust?
Yes – fully ATEX-certified for GAS (G) and DUST (D) atmospheres.

Is the ULPA filter included?
Yes – U15 ULPA is standard.

Which filtration system does it use?
MRP – Manual Reverse Purge with a static-dissipative purge cartridge.

Is it suitable for pharmaceutical use?
Yes – SS304 construction, ULPA filtration and ISO Class 4 compatibility.

Related articles

Technical specifications

All values are based on official Tiger-Vac documentation. Specifications may change without notice.
SpecificationData
ATEX classificationII 1/2GD – Ex h IIC T6 Ga · Ex h IIIC T50°C Da (internal) · Ex db h IIB T4 Gb · Ex h tb IIIC T135°C Db IP65 (external)
CertificatesIECEx LCI 10.0040X · LCIE 03 ATEX 6295 X
Voltage400 V
Frequency50 Hz
Phase3-phase
Power4 kW / 4,000 W
Amperage8.2 A
Airflow299 m³/h
Vacuum3,380 mm H₂O
VRV2,030 mm H₂O
Sound level75 dB(A)
Suction inletØ63.5 mm
Filter cleaningMRP – Manual Reverse Purge
Main filterStatic-dissipative reverse-purge cartridge
Final filterULPA U15 – 99.999% @ 0.12 µm
Recovery tank50 L SS304 (DT)
MaterialsStainless steel 304 (except cart)
Dimensions81 × 69 × 210 cm
Cable length10 m
Weight60 kg