ATEX Dust vacuum cleaner

Depureco FILTER HOPPER 570

  • Upstream pre-separator for central vacuum systems with larger dust volumes
  • Open discharge Ø250 mm -- requires separate DISCHARGE SYSTEM downstream
  • Combined with CVS Z22 or CVS ROOTS Z22 vacuum unit + DV AIR/DV AIR WB main filter
  • Cartridge filter class M (120,000 cm²) -- high surface for lower pressure drop
  • SP-Reverse jet cleaning included -- for continuous operation
  • Suited to continuous discharge via rotary valve, butterfly or big-bag frame
  • Non-ATEX -- for non-explosive dust environments
Depureco FILTER HOPPER 570
Certified to
  • ATEX Directive 2014/34/EU -- -
  • EN 17348:2022 (harmonized March 2023)
  • IEC 60335-2-69 (industrial vacuums)

Depureco FILTER HOPPER 570

A **pre-separator** is installed upstream of the main filter unit (DV AIR / DV AIR WB) and catches coarse particles **before** they reach the main filter's cartridges. This significantly extends the main filter's life, reduces pressure drop in the system and saves compressed air for the pulsejet cleaning. The Depureco FILTER HOPPER 570 is a **passive pre-separator with an open discharge flange** (non-ATEX) for central vacuum systems. The unit has a **cartridge filter class M** (120,000 cm² antistatic polyester), inlet Ø100 mm on the vacuum unit side and Ø100 mm on the vacuum spot side, discharge Ø250 mm. The discharge is an open flange and **requires a separate DISCHARGE SYSTEM** downstream (rotary valve, butterfly or big-bag frame -- see accessories page). SP-Reverse jet pulsejet cleaning is **included**. The unit is **passive** and **must be mandatorily combined with a vacuum unit** (CVS Z22 or CVS ROOTS Z22). Footprint 570 x 570 mm, height 1928 mm. Note: **not ATEX-certified**.

Applications

  • Upstream pre-separator for central vacuum systems with larger dust volumes
  • Open discharge Ø250 mm -- requires separate DISCHARGE SYSTEM downstream
  • Combined with CVS Z22 or CVS ROOTS Z22 vacuum unit + DV AIR/DV AIR WB main filter
  • Cartridge filter class M (120,000 cm²) -- high surface for lower pressure drop
  • SP-Reverse jet cleaning included -- for continuous operation
  • Suited to continuous discharge via rotary valve, butterfly or big-bag frame
  • Non-ATEX -- for non-explosive dust environments

Technical specifications

ATEX marking-
Internal / external zone- / -
Motor typeIngen motor -- passiv pre-separator; luftflow leveres af tilknyttet sugeaggregat
Duty cycle
Filter classM class
Filter typePatronfilter klasse M (120.000 cm² antistatisk polyester, EN 60335-2-69 / IFA-BGIA M-PES)
Primary filterPatronfilter (antistatisk polyester), 120.000 cm² total
Cleaning systemSP-Reverse jet pulsejet-rens (trykluft-drevet, differenstryk-styret) -- **inkluderet**
Collection systemNo collection -- separate filtration and collection unit required
MaterialLakeret staal-kabinet
IP class-
Voltage-
Dimensions (L × W × H)570 x 570 x 1928 mm

Options

Accessories and safety systems

Accessories page with discharge and safety systems

Discharge and safety systems designed for this series. See details, SKUs and compatibility rules on the accessories page.

See all accessories and safety systems →

Included accessory: Big-Bag discharge frame

Big-Bag Discharge Frame (P12386)

SKU P12386

The Big-Bag Discharge Frame (P12386) is the dedicated steel frame that supports the FILTER HOPPER and keeps the big bag tensioned during discharge. The frame attaches directly to the hopper funnel and provides a closed dust discharge without any additional discharge mechanics.

Questions and answers

What is a pre-separator and why use one?

A pre-separator is a passive filter unit placed between the suction point and the main filter unit. Its role is to **catch the coarse particles first**, so the main filter unit (e.g. DV AIR or DV AIR WB) only has to handle the fine residual dust. This gives three concrete benefits: (1) the main filter's cartridges last longer (less load), (2) pressure drop in the plant is lower and more constant (less pulsejet cleaning needed), and (3) the bulk of the dust is already collected at the pre-separator level where it is easier to handle. The catalogue is explicit: pre-separators **must be mandatorily combined with a suction unit** (CVS Z22 or CVS ROOTS Z22).

What is Depureco FILTER HOPPER 570, and how does it work in practice?

Depureco FILTER HOPPER 570 is a passive pre-separator with cartridge filter class M (120,000 cm² antistatic polyester). Discharge is via an **open Ø250 flange** and requires a separate DISCHARGE SYSTEM downstream (rotary valve, butterfly or big-bag frame -- see our accessories page). This configuration suits larger dust volumes where automatic, continuous discharge is required. The vacuum unit's air flow enters via the Ø100 mm inlet (on the vacuum unit side) or Ø100 mm (on the vacuum spot side) and passes through the cartridge filter area. SP-Reverse jet pulsejet cleaning is **included** on this model.

Why cartridge filter over star filter at this size?

Cartridge filters have significantly higher filter surface area per volume than star filters -- this gives lower air velocity over the filter face, lower pressure drop and longer life at the same dust load. For this reason, the catalogue chose a cartridge filter at this size (and on all non-bin variants), where flow and dust volume are expected to be greater. SP-Reverse jet pulsejet cleaning is **included** on this model to keep the filter clean under continuous operation.

Is Depureco FILTER HOPPER 570 ATEX-certified?

No. The catalogue lists this family of pre-separators WITHOUT ATEX marking -- they are thus non-ATEX and must not be used in explosive atmospheres (Zone 20/21/22). If your plant requires ATEX operation, the pre-separator solution must be specifically engineered (and combined with DV AIR Z22 / DV AIR WB Z22 as the main filter). The antistatic polyester media reduces electrostatic buildup but does not replace ATEX type approval.

Which vacuum units can Depureco FILTER HOPPER 570 be combined with?

The recommended matches are the CVS Z22 range (side-channel blower) and the CVS ROOTS Z22 range (Roots pump) -- these are the same two vacuum units that DV AIR and DV AIR WB are sized for. Choice of vacuum unit depends on vacuum needs, plant length and duty profile. We help with sizing based on pipe lengths, take-off points and dust characteristics. Note that pre-separators are placed **upstream** of the main filter unit, so they share the vacuum unit's flow and vacuum with the main filter -- the sizing must account for the combined pressure drop.

What are the installation requirements for Depureco FILTER HOPPER 570?

The unit is delivered as a complete module on a fixed frame. The customer must ensure: (1) installation space with ceiling height for 1928 mm (footprint 570 x 570 mm); (2) connection on the vacuum unit side (Ø100 mm) and on the vacuum spot side (Ø100 mm); (3) connection to a separate DISCHARGE SYSTEM on the discharge flange Ø250 mm (see accessories page); (4) compressed air supply (typically 5-6 bar) to the SP-Reverse jet cleaning system; (5) correct mechanical anchoring and signage (not ATEX-approved); and (6) planned access to the filter inspection door for filter checks and replacement.

Does Particulair handle installation and service?

Yes. We offer both installation and commissioning of central filter solutions and mobile systems. For pre-separators the installation includes: matching with vacuum unit and main filter unit, connection of DISCHARGE SYSTEM (see accessories page), compressed-air supply for SP cleaning, and commissioning. We also offer service agreements with planned filter inspections, filter replacement and spare-parts access. See 'About Particulair' for geographic coverage.