Accessories · Accessory
CONNECT 241 AS for 356
CONNECT 241 AS for 356 is a black spiral hose connector with thread that the manufacturer lists for hose 356. It is stated to be permanently antistatic with a resistance below 10⁹ Ω and is described as highly abrasion-resistant, resistant to microbes and hydrolysis and with good resistance to oil, petrol and chemicals. It can be used from −40 to +90 °C, briefly up to +125 °C, and is available for hoses with inner Ø from 40 to 150 mm.
- Antistatic
- Oil and petrol resistant
- −40 to +90 °C
Technical specifications
The product's key specifications are briefly summarised below.
| Type | Spiral hose connector with thread, screw-on |
|---|---|
| Colour | Black |
| Electrical resistance | Cover antistatic, below 10⁹ Ω (wall: volume and surface resistance approx. 10⁹ Ω) |
| Temperature | −40 to +90 °C, briefly +125 °C |
| Hoses | 356 |
| Manufacturer SKU | 2418501 |
Dimensions and ordering
The table shows the standard sizes of the connector.
| Inner Ø |
Total length |
Weight |
Article no. |
|---|---|---|---|
| 40 | 85 | 0.09 | 24100408501 |
| 50 | 90 | 0.14 | 24100508501 |
| 60 | 90 | 0.16 | 24100608501 |
| 70 | 100 | 0.19 | 24100708501 |
| 75 | 107 | 0.23 | 24100758501 |
| 80 | 112 | 0.26 | 24100808501 |
| 100 | 122 | 0.42 | 24101008501 |
| 150 | 155 | 0.96 | 24101508501 |
Inner Ø is the inner Ø of the hose; the diameter of the receiving nozzle is the same. Weight is per piece. Length of the receiving nozzle and screw-in depth of the hose: Ø 40: 44 and 40 mm. Ø 50: 49 and 41 mm. Ø 60: 49 and 41 mm. Ø 70: 52 and 44 mm. Ø 75: 60 and 47 mm. Ø 80: 60 and 52 mm. Ø 100: 65 and 57 mm. Ø 150: 85 and 70 mm.
Compatible with these hoses
This accessory is qualified by the manufacturer for the following hoses.
Related hoses
Hoses often considered alongside this one. Suggestions are based on the same category and similar properties.
Frequently asked questions
Is the connector approved for ATEX?
The manufacturer states that the connector is antistatic with a resistance below 10⁹ Ω but does not state any ATEX use. Whether it can be used in a particular zone depends on the overall zone assessment of the installation.