ATEX Combi vacuum cleaner

Tiger-Vac CD-100L (DT) EX (MFS) CAT. 2GD Z1-21 -- 4 kW

Three-phase TEFC ATEX II 1/2GD high-capacity combined vacuum -- 100 L detachable tank, 4 kW, 299 m3/h, 2.5" CAMLOCK, MFS, for Zone 1+2 gas and Zone 21+22 dust

  • Pharma and chemical industry plants with combined zone marking and large collection volume
  • Refinery boundary zones with simultaneous gas Zone 1 and dust Zone 21
  • Process production where the 100 L tank gives long emptying intervals
  • Sites where 2.5" CAMLOCK quick-coupling and 4 kW motor are the optimal combination
  • Industrial housekeeping with continuous 24/7 operation
Tiger-Vac CD-100L (DT) EX (MFS) CAT. 2GD Z1-21 -- 4 kW -- Three-phase TEFC ATEX II 1/2GD high-capacity combined vacuum -- 100 L detachable tank, 4 kW, 299 m3/h, 2.5" CAMLOCK, MFS, for Zone 1+2 gas and Zone 21+22 dust
Certified to
  • ATEX Directive 2014/34/EU -- II 1/2GD External: Ex db h IIB T4 Gb -- Ex h tb IIIC T135 C Db IP65 -- Internal: Ex h IIC T6 Ga -- Ex h IIIC T50 C Da -- -5 C <= Ta <= +37 C -- EN 17348 DT -- LCIE 03 ATEX 6295 X -- IECEx LCI 10.0040X -- ATEX 3rd party -- 2.5" CAMLOCK 63,5 mm sugeport
  • EN 17348:2022 (harmonized March 2023)
  • IEC 60335-2-69 (industrial vacuums)

Tiger-Vac CD-100L (DT) EX (MFS) CAT. 2GD Z1-21 -- 4 kW

The Tiger-Vac CD-100L (DT) EX (MFS) CAT. 2GD Z1-21 in 4 kW configuration is Tiger-Vac's high-capacity ATEX II 1/2GD combined vacuum. Marked II 1/2GD 3rd party (LCIE 03 ATEX 6295 X + IECEx LCI 10.0040X) -- approved for internal Zone 20 + gas Zone 1 + dust Zone 21 simultaneously. 100 L AISI 304 detachable tank, three-phase 4 kW TEFC at 8.7 A delivers 299 m3/h at 3380 mmH2O and 72 dB(A). The star-shaped Teflon-coated 19,500 cm2 main filter is shaken mechanically by MFS, and the True Cyclone Separator increases separation efficiency. 2.5" CAMLOCK quick-coupling suction intake. HEPA H14 and ULPA U15 are options -- suitable for pharma and chemical industry applications where combined zone marking is required and high collection volume is critical.

Applications

  • Pharma and chemical industry plants with combined zone marking and large collection volume
  • Refinery boundary zones with simultaneous gas Zone 1 and dust Zone 21
  • Process production where the 100 L tank gives long emptying intervals
  • Sites where 2.5" CAMLOCK quick-coupling and 4 kW motor are the optimal combination
  • Industrial housekeeping with continuous 24/7 operation

Technical specifications

ATEX markingII 1/2GD External: Ex db h IIB T4 Gb -- Ex h tb IIIC T135 C Db IP65 -- Internal: Ex h IIC T6 Ga -- Ex h IIIC T50 C Da -- -5 C <= Ta <= +37 C -- EN 17348 DT -- LCIE 03 ATEX 6295 X -- IECEx LCI 10.0040X -- ATEX 3rd party -- 2.5" CAMLOCK 63,5 mm sugeport
Internal / external zone20 / 21
Motor type3-faset TEFC induktion -- eksplosionsbeskyttet (Ex db h IIB T4 Gb / Ex h tb IIIC T135 C Db IP65), 3rd party certified, kontinuerlig drift
Duty cycle
Airflow299 m³/h
Vacuum331 mbar (3380 mmH₂O)
Container100 L
Sound pressure72 dB(A)
Filter classH class
Filter typeHEPA H14 (EN 1822, 99,995 % MPPS) tilvalg upstream/downstream -- aerosol leak-testet, OSHA-compliant. ULPA U15 også tilvalg
Primary filterStar-shaped 19.500 cm2 PTFE main filter SD* (218637)
Cleaning systemManual Filter Shaker (MFS) m/True Cyclone Separator
Collection systemDetachable container
MaterialAISI 304 rustfri stål kabinet (undtagen cart -- som er heavy duty powder coated -- AISI 304 cart som tilvalg til pharma)
IP classIP65
Power4.0 kW
Current8.7 A
Voltage400 V / 50 Hz / 3~
InletØ 63.5 mm
Dimensions (L × W × H)1170 x 690 x 1680 mm
Weight164 kg

Options

Questions and answers

What is the difference between the 4 kW and 7.5 kW variants?

4 kW (112570B1, this page) delivers 299 m3/h at 3380 mmH2O at 8.7 A and 72 dB(A). 7.5 kW (112574B1) delivers 450 m3/h at 2345 mmH2O at 15 A and 75 dB(A) -- about 50 % more flow but 30 % lower vacuum. Weight: 164 kg vs 170 kg. Choose 4 kW for standard applications; choose 7.5 kW when you need higher air volume for longer hose lengths or multiple simultaneous suction points.

What is the True Cyclone Separator?

A passive pre-separator at the suction intake that uses centrifugal force to separate 70-80 % of the coarsest dust before it reaches the main filter. Significantly reduces filter loading and can extend filter life 3-5 times. This means longer intervals between MFS-shaker cycles and lower operating cost over time.

What is the manometer for?

The manometer on the intake side shows the vacuum level and gives the operator a quick visual signal of when the filter is becoming clogged (higher vacuum = more cake on the filter). It is also a safety function -- if the VRV valve opens due to blockage it is clearly visible on the manometer.

What hose type is used?

Standard is the supplied 500540D crushproof suction hose -- 50 mm x 4.5 m static conductive with 2.5" female CAMLOCK aluminium. Connects to the machine's 2.5" CAMLOCK intake. The hose can be replaced by the 500306D KANAFLEX explosion-proof hose (mandatory with conductive metal dust). 70 mm polyurethane hoses are also available for high-flow applications.

What is the ground continuity multimeter (211065B)?

A multimeter that measures resistance from the machine to ground -- must be under 10 ohm for safe use in ATEX zones. Measured before each shift to ensure that grounding is intact and static electricity can be safely discharged. Included as standard on CD-100L EX (MFS) 2GD models to simplify daily safety check.

Need advice on this model?