ATEX Dust vacuum cleaner

Tiger-Vac C-7 EX (4W)

Compact single-phase ATEX II 1/3D vacuum for Zone 20/22 -- 19 L disposable filter bag, HEPA H14 (4 pcs), 4-wheel dolly, 77.5 cm tall -- for general housekeeping and 3D printing

  • 3D printer housekeeping and additive manufacturing clean-up
  • General ATEX dust housekeeping in process production (Zone 22)
  • Housekeeping in pharma pilot and chemical laboratories with combustible dust
  • Cleaning of smaller machine components with ESD-sensitive dust
  • Cleaning stations where a larger vacuum is too bulky for the space
Tiger-Vac C-7 EX (4W) -- Compact single-phase ATEX II 1/3D vacuum for Zone 20/22 -- 19 L disposable filter bag, HEPA H14 (4 pcs), 4-wheel dolly, 77.5 cm tall -- for general housekeeping and 3D printing
Certified to
  • ATEX Directive 2014/34/EU -- II 1/3D Ex h tc IIIC T200 C Dc IP6X (External) -- Ex h IIIC T200 C Da (Internal) -- -5 C <= Ta <= +37 C -- EN 17348 DT -- LCIE 15 ATEX 3061 -- IECEx LCIE 15.0048
  • EN 17348:2022 (harmonized March 2023)
  • IEC 60335-2-69 (industrial vacuums)

Tiger-Vac C-7 EX (4W)

The Tiger-Vac C-7 EX (4W) is the compact single-phase explosion-protected vacuum from Tiger-Vac's C series -- just 77.5 cm tall and mounted on a 4-wheel dolly. Marked II 1/3D per EN 17348 DT and IECEx 3rd party (LCIE 15 ATEX 3061), suitable for internal Zone 20 + external Zone 22. Driven by a single-phase Ametek by-pass universal motor (1200 W / 1.2 kW / 5 A) delivering 194 m3/h at 2504 mmH2O and 72 dB(A). Includes 4 HEPA H14 filters (EN 1822, individually factory-tested) and a conductive recovery bag as standard. A 19 L disposable filter bag is the recovery medium. Ideal for 3D printer housekeeping, general process cleaning and applications where space is tight.

Applications

  • 3D printer housekeeping and additive manufacturing clean-up
  • General ATEX dust housekeeping in process production (Zone 22)
  • Housekeeping in pharma pilot and chemical laboratories with combustible dust
  • Cleaning of smaller machine components with ESD-sensitive dust
  • Cleaning stations where a larger vacuum is too bulky for the space

Technical specifications

ATEX markingII 1/3D Ex h tc IIIC T200 C Dc IP6X (External) -- Ex h IIIC T200 C Da (Internal) -- -5 C <= Ta <= +37 C -- EN 17348 DT -- LCIE 15 ATEX 3061 -- IECEx LCIE 15.0048
Internal / external zone20 / 22
Motor type1-faset Ametek by-pass universal-motor (1200 W / 1,2 kW / 5 A) -- T200 C overfladetemperatur
Duty cyclePeriodic
Airflow194 m³/h
Vacuum245 mbar (2504 mmH₂O)
Container19 L
Sound pressure72 dB(A)
Filter classH class
Filter typeHEPA H14 (EN 1822, 99,99 % MPPS), individuelt fabriks-testet -- 4 x HEPA-filtre i kabinettet (212304B-HD, 215372, 211854) -- 20.253 cm2 filterflade
Primary filterHovedfilter PTFE/Epitropic polyester SD* m/stainless steel bands (218627 eller 215393-SD afhængigt af model)
Cleaning systemIngen aktivt rens-system
Collection systemDetachable container
MaterialAISI 430 rustfri stål kabinet (AISI 304 tank som tilvalg på 4W EU-versionen)
IP classIP6X
Power1.2 kW
Current5 A
Voltage220-240 V / 50-60 Hz / 1~
InletØ 60 mm
Dimensions (L × W × H)430 x 430 x 775 mm
Weight23 kg

Options

Questions and answers

What does II 1/3D mean on this machine?

II 1/3D means category 1 internally and category 3 externally -- the highest protection level (Da) inside the collection tank and the lowest on the outer housing (Dc). In practice: the unit can recover from Zone 20 (dust continuously present) even though the powerhead itself sits in Zone 22 (dust rarely present). That is the typical ATEX housekeeping configuration in process production -- recovery happens at a hazardous point while the operator stays in the less hazardous area.

What motor is fitted?

The Tiger-Vac C-7 EX (4W) delivers 1200 W / 1.2 kW / 5 A with a single-phase Ametek by-pass universal motor. Surface temperature is T200 C. The BLSD (brushless) version is available as an option for extended motor life and T85 C surface temperature.

What is the HEPA H14 setup on this model?

Every unit is supplied with 4 individually factory-tested HEPA H14 filters in the housing (212304B-HD as primary HEPA, 215372 and 211854 as tertiary). Total filter area is 20,253 cm2 -- about 2 m2. The class is H14 per EN 1822, equivalent to 99.995 % MPPS (Most Penetrating Particle Size). That is the requirement EN 17348 DT places on ATEX vacuums for combustible dust including asbestos, lead and pharma CMR substances.

Can it pick up liquids?

No. The entire C series is certified EN 17348 DT -- dry recovery only. For wet/dry recovery in Zone 20/22, a dedicated WD model must be used, such as the CD-63L EX (W&D) variants. For liquid recovery in ATEX Kombi zones (II 2GD), see the ATEX-12A (4W) or (2+2W).

How is the unit wired up?

The power outlet is not included -- it must be fitted by an electrician per local regulations (typically 16 A schuko or blue CEE in Europe). 220-240 V 50/60 Hz single-phase. The cord is 10.6 m. The ATEX marking covers the vacuum cleaner itself -- the outlet and supply must be ATEX-rated if the unit is supplied from inside Zone 22 (II 3D-rated outlet). Supply from a non-classified area places no requirement on the outlet itself.