ATEX Dust vacuum cleaner

Tiger-Vac CD-100L (DT) EX (MFS) 2D Z21 -- 7.5 kW

Mobile three-phase TEFC ATEX dust vacuum for internal Zone 20 and external Zone 21 (II 1/2D) -- 100 L detachable tank, HIGH-FLOW 7.5 kW motor, 450 m3/h, Manual Filter Shaker (MFS), PTFE star-shaped main filter

  • High-flow applications where 450 m3/h is needed for long hose runs or multiple pickup points
  • High-capacity recovery in Zone 20/21 with high dust volume
  • Industrial central vacuum solutions where air volume is the primary parameter
  • Production with connection to multiple workstations simultaneously
  • Requirements for long continuous duty without manual intervention
Tiger-Vac CD-100L (DT) EX (MFS) 2D Z21 -- 7.5 kW -- Mobile three-phase TEFC ATEX dust vacuum for internal Zone 20 and external Zone 21 (II 1/2D) -- 100 L detachable tank, HIGH-FLOW 7.5 kW motor, 450 m3/h, Manual Filter Shaker (MFS), PTFE star-shaped main filter
Certified to
  • ATEX Directive 2014/34/EU -- II 1/2D Ex h tb IIIC T135 C Db IP65 -- Intern: Ex h IIIC T50 C Da -- LCIE 03 ATEX 6295 X -- IECEx LCI 10.0040X -- EN 17348 DT
  • EN 17348:2022 (harmonized March 2023)
  • IEC 60335-2-69 (industrial vacuums)

Tiger-Vac CD-100L (DT) EX (MFS) 2D Z21 -- 7.5 kW

The Tiger-Vac CD-100L (DT) EX (MFS) 2D Z21 in the 7.5 kW variant is the high-flow version of the CD-100L series -- marked II 1/2D to EN 17348 DT. The more powerful three-phase TEFC motor (7.5 kW, 15 A) delivers 450 m3/h at 2345 mmH2O -- a higher air volume than the 3.4 kW variant at the cost of slightly lower vacuum. The model is particularly suited to applications with long hose runs, multiple simultaneous pickup points, or uses where large air volumes must be handled. The main filter is the same static-dissipative SD* PTFE star-shaped filter with 12 folds (218637) and 19,500 cm2 surface as the 3.4 kW variant. Manual Filter Shaker (MFS) cleans the filter mechanically without opening the machine. The suction inlet is 70 mm direct connection (no CAMLOCK) to accommodate the higher air volume. NOTE: HEPA/ULPA filter surface size was not stated on the factsheet for the 7.5 kW variant -- contact us for current value before quotation.

Applications

  • High-flow applications where 450 m3/h is needed for long hose runs or multiple pickup points
  • High-capacity recovery in Zone 20/21 with high dust volume
  • Industrial central vacuum solutions where air volume is the primary parameter
  • Production with connection to multiple workstations simultaneously
  • Requirements for long continuous duty without manual intervention

Technical specifications

ATEX markingII 1/2D Ex h tb IIIC T135 C Db IP65 -- Intern: Ex h IIIC T50 C Da -- LCIE 03 ATEX 6295 X -- IECEx LCI 10.0040X -- EN 17348 DT
Internal / external zone20 / 21
Motor type3-faset TEFC-motor, eksplosionssikret (Ex h tb IIIC T135 C Db), 7,5 kW / 15 A, 400 V / 50 Hz
Duty cycle
Airflow450 m³/h
Vacuum230 mbar (2345 mmH₂O)
Container100 L
Sound pressure75 dB(A)
Filter classH class
Filter typeHEPA nedstroems (212202, 11" high, 99,995 % H14) eller (212202A, 22" high, 99,99 %) -- tilvalg. HEPA/ULPA filter surface size: TBD (ikke angivet paa factsheet -- kontakt producent)
Primary filterMain Filter Assembly, SD* PTFE star-shaped (12) filter (pleated) -- part 218637, overflade 19.500 cm2
Cleaning systemManual Filter Shaker (MFS) -- mekanisk rystning af det statisk ledende PTFE star-shaped hovedfilter
Collection systemDetachable container
MaterialAISI 304 rustfri staal (cart: heavy-duty powder coated)
IP classIP65
Power7.5 kW
Current15 A
Voltage400 V / 50 Hz / 3~
InletØ 70 mm
Dimensions (L × W × H)1170 x 690 x 1680 mm
Weight175 kg

Questions and answers

Why isn't the HEPA/ULPA filter surface size listed?

On Tiger-Vac's official factsheet for CD-100L 2D Z21 the 'HEPA/ULPA Filter Surface Size' column is filled for the 3.4 kW variant (19,500 cm2) but blank for the 7.5 kW variant. This is most likely because the filter topology is identical (same HEPA options 212202 and 212202A), but we confirm the value before ordering to avoid incorrect specification. Contact us when ready for quotation and we'll retrieve the current value directly from Tiger-Vac.

When should I choose 7.5 kW over 3.4 kW?

Choose 7.5 kW if: you have long hose runs (over 10 m) where pressure drop reduces the 3.4 kW variant's effectiveness; you need to connect multiple pickup points simultaneously (e.g. two or three workstations with their own hoses); or you operate a central vacuum solution where maximum air volume is required. Choose 3.4 kW if: standard use with a single 4-7 m hose; vacuum is more important than air volume (higher vacuum - 2540 vs 2345 mmH2O - gives better performance on fine or sticky dust); or the electrical supply only supports 8 A (7.5 kW requires 15 A and matching cable/fuse sizing).

What is the difference between the suction inlets (70 mm direct vs 2.5" CAMLOCK)?

The 3.4 kW variant has a 2.5" CAMLOCK (63.5 mm) suction inlet, designed for crushproof suction hose 500540D with matching camlock. The 7.5 kW variant has a 70 mm direct connection -- a larger cross-section allowing higher air volume (450 m3/h) with less turbulence. The difference is a deliberate design choice: a 2.5" camlock limits flow to about 320 m3/h before turbulence increases, while 70 mm handles 450 m3/h without issue. If you upgrade from 3.4 kW to 7.5 kW you must also choose a hose in the larger dimension (typically Ø70 mm) to exploit the full performance.

Can it pick up liquids?

No. The CD-100L EX (MFS) 2D Z21 is certified EN 17348 DT -- dry-only recovery. For wet/dry in Zone 20/21 a dedicated WD model must be specified.

Which poly-liner retainer should be used with the 7.5 kW variant?

The 7.5 kW motor is above 5 HP (5 HP = 3.73 kW, so 7.5 kW = about 10 HP), and the standard poly-liner retainer plate 213780 is only approved for motors up to 5 HP. For the 7.5 kW variant one must use 213780A -- the reinforced version specifically for 7.5 HP (and above) motors. Without the correct retainer the poly liner can be sucked into the filter chamber under strong vacuum.

What is included in delivery?

CD-100L EX (MFS) 7.5 kW ships with: main filter 218637 (SD* PTFE star-shaped 12 pleats, 19,500 cm2), manometer, Ø50 mm SD tool kit with 2.5" camlock adapter (crushproof hose 500540D, wand 500160, universal tool 500161A, crevice tool 500156B, dusting brush 501184A, conical nozzle 500230), ground-continuity multimeter 211065B, heavy-duty powder coated cart. Options: downstream HEPA H14 11" (212202) or 22" (212202A), conductive poly liner (212106AS), reinforced poly-liner retainer plate (213780A, REQUIRED for 7.5 HP motors), upgrade to Ø70 mm accessories to exploit full 450 m3/h performance.

Need advice on this model?