Tiger-Vac CD-2600 EX CR (MFS) Z22
Single-phase TEFC ATEX II 3D vertical-mount cleanroom vacuum -- 36 L tank on Carriage Base, 306 m3/h, 68 dB(A), ISO Class 4-compatible, for pharma and tablet recovery
- Pharma tablet recovery in ATEX cleanrooms (ISO Class 4 compatible)
- Dust housekeeping in cleanrooms with limited floor space -- vertical Carriage Base
- Process equipment connection for continuous dust extraction
- Pharma pilot plants where low sound level (68 dB(A)) is critical
- ATEX housekeeping where single-phase 230 V is required
- ATEX Directive 2014/34/EU -- II 3D Ex h tc IIIC T125 C Dc IP65 -- -5 C <= Ta <= +37 C -- EN 17348 DT -- ATEX 1st party certified -- ISO Class 4 cleanroom-compatible
- EN 17348:2022 (harmonized March 2023)
- IEC 60335-2-69 (industrial vacuums)
Tiger-Vac CD-2600 EX CR (MFS) Z22
The Tiger-Vac CD-2600 EX CR (MFS) Z22 (CR = Cleanroom) is Tiger-Vac's vertically mounted single-phase ATEX II 3D vacuum for pharma and cleanroom applications. Marked II 3D Ex h tc IIIC T125 C Dc IP65, EN 17348 DT, and is ISO Class 4 cleanroom compatible. A 230 V TEFC induction motor (2 kW, 13 A) delivers 306 m3/h at 2030 mmH2O and just 68 dB(A) -- the lowest noise in the CD series. The vertical Carriage Base (CB) construction gives a small 51 x 66 cm footprint but 191 cm height -- ideal for areas with limited floor space. 36 L AISI 304 detachable tank, star-shaped Teflon-coated main filter with MFS, True Cyclone Separator. Often used in pharma pilot plants for tablet recovery, dust housekeeping in cleanrooms, and process equipment connection where a tall cylindrical shape fits better than a short, wide CD-55L.
Applications
- Pharma tablet recovery in ATEX cleanrooms (ISO Class 4 compatible)
- Dust housekeeping in cleanrooms with limited floor space -- vertical Carriage Base
- Process equipment connection for continuous dust extraction
- Pharma pilot plants where low sound level (68 dB(A)) is critical
- ATEX housekeeping where single-phase 230 V is required
Technical specifications
| ATEX marking | II 3D Ex h tc IIIC T125 C Dc IP65 -- -5 C <= Ta <= +37 C -- EN 17348 DT -- ATEX 1st party certified -- ISO Class 4 cleanroom-compatible |
|---|---|
| Internal / external zone | -- / 22 |
| Motor type | 1-faset TEFC induction-motor, eksplosionsbeskyttet -- kontinuerlig drift 24/7 |
| Duty cycle | Continuous |
| Airflow | 306 m³/h |
| Vacuum | 199 mbar (2030 mmH₂O) |
| Container | 36 L |
| Sound pressure | 68 dB(A) |
| Filter class | H class |
| Filter type | HEPA H14 (EN 1822, 99,995 % MPPS), aerosol leak-testet, OSHA-compliant -- HEPA upstream/downstream som tilvalg, ULPA U15 også tilvalg |
| Primary filter | Star-shaped Teflon-belagt SD-hovedfilter med Manual Filter Shaker |
| Cleaning system | Manual Filter Shaker (MFS) |
| Collection system | Detachable container |
| Material | AISI 304 rustfri stål (krop og tank) |
| IP class | IP65 |
| Power | 2.0 kW |
| Current | 13 A |
| Voltage | 230 V / 50 Hz / 1~ |
| Inlet | Ø 50 mm |
| Dimensions (L × W × H) | 660 x 510 x 1910 mm |
| Weight | 112 kg |
Questions and answers
Why vertical mounting on a Carriage Base?
The Carriage Base (CB) keeps the vacuum in an upright cylindrical form 191 cm tall. This gives a footprint of just 51 x 66 cm -- about a third of a standard horizontal CD-55L. Suitable for pharma pilot plants, cleanrooms and small process areas where floor space is at a premium. The CB construction is also easier to integrate with process equipment via the top of the tank (for connecting pickup pipes from process machinery).
What does ISO Class 4 cleanroom compatible mean?
ISO Class 4 (formerly Class 10) is a cleanroom class allowing maximum 352 particles above 0.5 micron per m3 of air. The CD-2600 in the optional ULPA U15 configuration can meet this requirement because ULPA filtration captures 99.999 % of particles down to 0.12 micron. The vacuum must be placed in the cleanroom or connected to the cleanroom's exhaust system. Note: with the standard MFS cloth filter (without HEPA/ULPA option) the CD-2600 is NOT ISO 4 compatible -- HEPA or ULPA is an optional upgrade for pharma applications.
What does "CR" stand for in the model name?
CR stands for Cleanroom -- i.e. the variant designed for pharma and cleanroom applications. The vertical Carriage Base and low sound level (68 dB(A)) are both cleanroom-oriented design choices. Other CD-2600 variants (without CR) exist with horizontal mounting or three-phase 400 V motors for more industrial applications.
Can it pick up liquids or tablets?
Liquids: no -- the CD-2600 is Dry Recovery Only per EN 17348 DT. Liquids can however be collected in a separate tank (contact us for configuration). Tablets: yes -- Tiger-Vac specifically highlights in the brochure that the CD-2600 EX CR "can also be used for the recovery of tablets in the Pharmaceutical industry". Tablets fall into the 36 L AISI 304 tank without being crushed by the motor's vacuum flow, making it suitable for pharma tablet reject recovery.
Why 68 dB(A) -- so low for a TEFC motor?
The CD-2600's vertical construction isolates the motor's cooling fan from the environment via a sound-damping shroud and a silencer on the exhaust. The larger 36 L tank also contributes as a passive damping volume. The result is 68 dB(A) -- about 7 dB lower than the standard CD-55L Z22 at 75 dB(A). This makes the CD-2600 EX CR one of the quietest industrial ATEX vacuums on the market.