Delfin DG 50 EXP PN
Three-phase ATEX vacuum with side-channel blower and pneumatic filter cleaning -- Zone 22 self-certified to EN 17348:2022, 4 kW, 100 L container
- Medium-sized ATEX Zone 22 productions running continuously with no time for manual filter cleaning
- Fine and abrasive dust types where pressure drop would make manual cleaning impractical
- Pharmaceutical and chemical process plants requiring stable airflow across the shift
- Central-vacuum setups where filter access is restricted after installation
- Wood, metal and composite industries where production cannot stop for filter service
- ATEX Directive 2014/34/EU -- II 3D Ex h tc IIIC T80°C (Int)/T165°C (Ext) Dc
- EN 17348:2022 (harmonized March 2023)
- IEC 60335-2-69 (industrial vacuums)
Delfin DG 50 EXP PN
The Delfin DG 50 EXP PN is the cartridge version of the DG 50 EXP: the same 4 kW side-channel blower and 100 L container, but with three self-cleaning antistatic class M cartridge filters (57,000 cm² total) and automatic pneumatic cleaning via compressed air during operation. The cabinet is 420 mm taller than the base model to accommodate the cleaning mechanism. Self-certified per EN 17348:2022 in category 3D and targeted at Zone 22 productions where continuous operation without manual filter stops outweighs compact build.
Applications
- Medium-sized ATEX Zone 22 productions running continuously with no time for manual filter cleaning
- Fine and abrasive dust types where pressure drop would make manual cleaning impractical
- Pharmaceutical and chemical process plants requiring stable airflow across the shift
- Central-vacuum setups where filter access is restricted after installation
- Wood, metal and composite industries where production cannot stop for filter service
Technical specifications
| ATEX marking | II 3D Ex h tc IIIC T80°C (Int)/T165°C (Ext) Dc |
|---|---|
| Internal / external zone | 22 / 22 |
| Motor type | Sidekanalblæser, 3-faset (trifase) |
| Duty cycle | Continuous |
| Airflow | 420 m³/h |
| Vacuum | 314 mbar (3200 mmH₂O) |
| Container | 100 L |
| Sound pressure | 70 dB(A) |
| Filter class | H class |
| Filter type | Klasse H HEPA, 26.000 cm² filterflade, H14-efficiens (99,995 % MPPS, EN 1822-5) |
| Primary filter | Antistatisk polyester klasse M patronfilter (3 stk, Ø150 x 500 mm, i alt 57.000 cm²) med automatisk pneumatisk rensning via trykluft under drift |
| Collection system | Plastic bag |
| Material | Lakeret stål med ABS-tilbehørskurv |
| IP class | IP65 |
| Power | 4.0 kW |
| Current | 8.4 A |
| Voltage | 400 V / 50 Hz / 3~ |
| Inlet | Ø 80 mm |
| Dimensions (L × W × H) | 660 x 1180 x 1870 mm |
| Weight | 145 kg |
Questions and answers
Is it ATEX-certified or self-certified?
It is self-certified by Delfin per EN 17348:2022 in category 3D. For category 3, the ATEX Directive permits manufacturer self-certification, provided the requirements of the harmonised standard are met. The marking is II 3D Ex h tc IIIC T80°C (Int)/T165°C (Ext) Dc.
Why are two vacuum values shown on the datasheet?
The model has a pressure relief valve fitted as standard. The valve admits false air at a set vacuum (2600 mmH²O) and thereby prevents the side-channel blower from being overloaded by blocked filters or a closed hose. The higher value (3200 mmH²O) is the theoretical maximum vacuum without valve activation. Both values are indicative and measured in new condition.
How is the dust collected — is there a bag?
The dust is collected in an open antistatic plastic bag placed in the container. The bag is held in place by a vacuum kit fitted at commissioning, which uses the container vacuum to press the bag against the container wall. The automatic pneumatic cleaning of the cartridge filters only shakes accumulated dust off the filter medium into the container — the bag principle is unchanged from the base Delfin DG 50 EXP model.
Is it certified for Zone 21 or Zone 20?
No. The model is categorised as 3D Dc, which only covers Zone 22. For Zone 21 or internal Zone 20, a 1/2D or 1/3D model must be used — for example the Delfin MTL 301 1/3D, MTL 201 1/2D or DM2 EL 1/2D LP. Contact Particulair if you are unsure which zone classification your production requires.
Can it run continuously for 8-16 hours?
Yes. The side-channel blower is oil-free and has long service life under continuous operation — that is the reason the technology is preferred on the MTL/DG range over bypass or brushless motors. The pressure relief valve protects against overload from filter blockage, the motor is rated for continuous duty (S1), and the PN version's pneumatic filter cleaning further extends the interval between manual filter service stops.
What does PN mean, how does the pneumatic filter cleaning work, and when should I choose PN over the base model?
PN stands for pneumatic cleaning system (Italian: pulizia neumatica). The three class M cartridge filters are mounted vertically above the collection container, and during operation a controlled solenoid-valve system sends short compressed-air pulses into the clean side of the cartridges at fixed intervals. The pulse shakes the accumulated dust off the filter medium from the inside so it falls into the collection container — without interrupting suction. Over time this significantly extends the operating interval between manual filter service stops: the base model requires manual shaking or cleaning when the star/pocket filter clogs; the PN version keeps itself clean during operation. Choose PN if (a) you run continuously and manual cleaning would force a production stop, (b) your dust is fine or greasy and clogs the primary filter quickly, or (c) you have a central vacuum installation with limited filter access. Choose the base Delfin DG 50 EXP model if cabinet height is a constraint (PN is 420 mm taller) or if compressed air is not available at the installation site.