ATEX Dust vacuum cleaner

Delfin DG 70 EXP

Three-phase ATEX vacuum with side-channel blower – category 1/3D (internal Zone 20, external Zone 22) to EN 17348, 5.5 kW, 100 L container

  • Large ATEX Zone 22 production areas with high dust loads
  • Continuous operation requiring 100 L collection and extended filter life
  • Metal and composite industry with fine abrasive dust
  • Pharmaceutical process plants requiring high airflow and HEPA fine filtration
  • Process plants where both flow and vacuum must be kept high across the shift
Delfin DG 70 EXP – Three-phase ATEX vacuum with side-channel blower – category 1/3D (internal Zone 20, external Zone 22) to EN 17348, 5.5 kW, 100 L container
Certified to
  • ATEX Directive 2014/34/EU – II 1/3D Ex h tb IIIC T135°C (Int)/T195°C (ext) Da/Dc
  • EN 17348:2022 (harmonized March 2023)
  • IEC 60335-2-69 (industrial vacuums)

Delfin DG 70 EXP

The Delfin DG 70 EXP is the mid-range model in Delfin's 100-litre DG range: a 5.5 kW side-channel blower delivering 530 m³/h airflow and 3600 mmH²O theoretical vacuum — the peak value in the family. The HEPA filter area is doubled from the DG 50 EXP to 52,000 cm², reducing pressure drop and extending filter life under continuous operation. ATEX-marked in category 1/3D (internal Zone 20, external Zone 22) to EN 17348 and suited to productions with high dust loads in Zone 22.

Applications

  • Large ATEX Zone 22 production areas with high dust loads
  • Continuous operation requiring 100 L collection and extended filter life
  • Metal and composite industry with fine abrasive dust
  • Pharmaceutical process plants requiring high airflow and HEPA fine filtration
  • Process plants where both flow and vacuum must be kept high across the shift

Technical specifications

ATEX markingII 1/3D Ex h tb IIIC T135°C (Int)/T195°C (ext) Da/Dc
Internal / external zone20 / 22
Motor typeThree-phase side-channel blower
Duty cycleContinuous
Airflow530 m³/h
Vacuum353 mbar (3600 mmH₂O)
Container100 L
Sound pressure72 dB(A)
Filter classH class
Filter typeClass H HEPA, 52,000 cm² filter area, H14 efficiency (99.995 % MPPS, EN 1822-5)
Primary filterStar/bag antistatic polyester M, 20,000 cm² / 420 mm
Collection systemPlastic bag
MaterialPainted steel with ABS accessory basket
IP classIP65
Power5.5 kW
Current11.0 A
Voltage400 V / 50 Hz / 3~
InletØ 80 mm
Dimensions (L × W × H)670 x 1200 x 1600 mm
Weight150 kg

Questions and answers

Which ATEX category does it have?

It is category 1/3D: the inside of the container is Zone 20, and the machine is used in external Zone 22. It complies with EN 17348 according to the Delfin price list 2026. The marking is II 1/3D Ex h tb IIIC T135°C (Int)/T195°C (ext) Da/Dc.

Why are two vacuum values shown on the datasheet?

The model has a pressure relief valve fitted as standard. The valve admits false air at a set vacuum (3000 mmH²O) and thereby prevents the side-channel blower from being overloaded by blocked filters or a closed hose. The higher value (3600 mmH²O) is the theoretical maximum vacuum without valve activation. Both values are indicative and measured in new condition.

How is the dust collected — is there a bag?

The dust is collected in an open antistatic plastic bag placed in the container. The bag is held in place by a vacuum kit fitted at commissioning, which uses the container vacuum to press the bag against the container wall. This prevents the bag from collapsing or being drawn into the filter during operation.

Can it be used in external Zone 21?

No. It is category 1/3D, which covers internal Zone 20 and external Zone 22. For external Zone 21, a 1/2D model must be used — for example the Delfin MTL 201 1/2D or DM2 EL 1/2D LP. Contact Particulair if you are unsure which zone classification your production requires.

Can it run continuously for 8-16 hours?

Yes. The side-channel blower is oil-free and has long service life under continuous operation — that is the reason the technology is preferred on the MTL/DG range over bypass or brushless motors. The pressure relief valve protects against overload from filter blockage, and the motor is rated for continuous duty (S1).

Why does the DG 70 EXP have twice the HEPA filter area of the DG 50?

A larger HEPA area reduces air velocity through the filter and thus the pressure drop. On the DG 70 EXP, the HEPA area is 52,000 cm² versus the DG 50 EXP's 25,000 cm² — a doubling. This gives longer filter life, less frequent manual cleaning, and better handling of fine dust. The primary filter (star/pocket) is 30,000 cm² on the DG 50 EXP and 20,000 cm² on the DG 70 EXP; air load on the primary filter is 140 m³/m²/h on the DG 50 EXP and 176 m³/m²/h on the DG 70 EXP. The cabinet is 150 mm taller than the DG 50 EXP (1600 vs 1450 mm according to the Delfin price list 2026).

Need advice on this model?