ATEX Areas • Gas Zone 1 • Dust Zone 21 • ISO Class 4
SSAT-2L (HH) AIR TIGER
Air-driven handheld ATEX vacuum (II 2GD) for Zone 1 gas and Zone 21 dust. No electrical or moving parts, temperature class T6 (max. 85 °C). Dry recovery only, HEPA H14 as standard, 1.9 L conductive disposable bag, AISI 304 stainless steel and 5 kg.
- ATEX II 2GD — Zone 1 gas + Zone 21 dust
- Handheld with shoulder strap — where there is no room for a cart
- HEPA H14 as standard — aerosol leak tested
- AISI 304 stainless steel — ISO Class 4
- Static dissipation below 10 ohms — whole unit
- No electrical or moving parts — temperature class T6
- Compressed air 5.5 bar — compressor of at least 15 HP
About SSAT-2L (HH) AIR TIGER
The Tiger-Vac SSAT-2L (HH) AIR TIGER is an air-driven handheld vacuum with a handle and shoulder strap. Suction is created by a single venturi, so the unit has neither electrical parts nor moving mechanical parts.
It is certified in temperature class T6 with a maximum surface temperature of 85 °C and marked II 2GD to EN 17348 DT for dry recovery of combustible dust. It is third-party certified under both ATEX (LCIE 03 ATEX 6310 X, Directive 2014/34/EU) and IECEx (LCIE 17.0076 X).
Dust is collected in a 1.9 L conductive disposable bag. The whole unit is AISI 304 stainless steel with under 10 ohms of resistivity, and HEPA H14 comes as standard. The unit weighs 5 kg and can be used in cleanrooms up to ISO Class 4.
The unit needs a compressor of at least 15 HP delivering 16.5–21.2 L/s at 5.5 bar. A 7.5 m air supply hose, a shoulder strap and a static conductive Ø38 mm tool kit are included.
Video
Technical Specifications
| Parameter | Value |
|---|---|
| Model | SSAT-2L (HH) AIR TIGER |
| Part Number | 111896 |
| ATEX Certification | LCIE 03 ATEX 6310 X, IECEx LCIE 17.0076 X |
| ATEX Marking | II 2GD |
| External Gas | Ex h IIC T6 Gb |
| External Dust | Ex h IIIC T85°C Db |
| Internal Classification | EN 17348 DT (dry recovery only) |
| Gas Zones | Zone 1, Zone 2 |
| Dust Zones | Zone 21, Zone 22 |
| Drive | Pneumatic venturi with no electrical or moving parts, T6 (max. 85 °C) |
| Air Consumption | 16.5–21.2 L/s (990–1272 Nl/min) |
| Air Pressure | 5.5 bar |
| Minimum Compressor | 15 HP |
| Air Flow | 85 m³/h |
| Max Vacuum | 2,030 mmH₂O (199 mbar) |
| Sound Level | 60 dB(A) (EN ISO 11203) |
| Suction Inlet | Ø38 mm |
| Container | 1.9 L, conductive disposable bag (212075-SD) |
| Material | AISI 304 stainless steel |
| Static Dissipation | Under 10 ohms, whole unit |
| HEPA Filter | H14, 99.995% at 0.3 µm (EN 1822, MPPS), 212303 — included |
| Main Filter | Conductive main filter (212078SD) |
| Filter Cleaning | None (manual) |
| Cleanroom Class | ISO Class 4 (ISO 14644-1) |
| Dimensions | 51 × 22 cm (L × W; height not stated) |
| Weight | 5 kg |
| Air Supply Hose | Ø 12.7 mm (1/2"), 7.5 m included |
| Recovery Mode | Dry recovery only |
Accessories and Filters
Ø38 mm Tool Kit (included)
Filtration system: bag 212075-SD, main filter 212078SD and HEPA 212303
Aircraft Case 215698 (optional)
HEPA H14 Filter 212303 (included)
Optional Upgrades
- Explosion-proof accessories under 10 ohms — KANAFLEX suction hose Ø38 mm × 1.5 m (381396D), 12.5 cm aluminium round brush (381185DA) and conical nozzle (383462D). Required by Tiger-Vac for conductive, metal and pyrotechnic dust
- Pre-filter — 218078SD
- Aircraft carrying case — with foam and wheels (215698)
Questions and Answers
II 2GD means equipment group II and category 2 for both gas and dust. The unit may be used in areas where an explosive atmosphere occasionally occurs during normal operation, i.e. Zone 1 for gas and Zone 21 for dust, and therefore also Zone 2 and 22. Ex h is the protection method for non-electrical equipment, IIC is the most demanding gas group, and T6 means a maximum surface temperature of 85 °C. Certificate LCIE 03 ATEX 6310 X is issued under Directive 2014/34/EU.
Venturi, airflow, vacuum, HEPA filter and ATEX marking are the same. The SSAT-2L (HH) is handheld with a shoulder strap, holds 1.9 L in a disposable bag and weighs 5 kg (length 51 cm). The SSAT-6L (BP) is carried on the back in a harness, has a 5.7 L tank and weighs 7 kg (height 64 cm).
No. The SSAT-2L (HH) is marked EN 17348 DT and is intended for dry recovery of combustible dust only. Flammable liquids require a unit marked EN 17348 LC.
Yes. Tiger-Vac states that the SSAT-2L (HH) can be used in cleanrooms up to ISO Class 4. The whole unit is AISI 304 stainless steel, and HEPA H14 comes as standard.
Standard. HEPA H14 (212303) at 99.995 % efficiency at 0.3 µm, tested to IEST-RP-CC001 and MPPS to EN 1822, is included. Every HEPA system is aerosol leak tested before it leaves the factory.
The certificate has two specific conditions of use: the unit must be grounded according to Tiger-Vac's instructions, and only accessories recommended by Tiger-Vac may be used. For conductive, metal and pyrotechnic dust Tiger-Vac requires the explosion-proof accessories under 10 ohms (381396D, 381185DA and 383462D). Ground continuity is checked with the included multimeter.
A compressor of at least 15 HP delivering 16.5–21.2 L/s (990–1272 Nl/min) at 5.5 bar, and a 1/2" (12.7 mm) air line. A 7.5 m air supply hose with quick disconnects is included. Suction is adjustable from 80" to 190" of water lift; Tiger-Vac ships the unit set to 80" (about 2030 mmH₂O) and 85 m³/h. Tiger-Vac states that performance may vary with the compressor.