Clean Room • Stainless steel • Dry recovery only

Tiger-Vac CR-1000 (SS)

The Tiger-Vac CR-1000 (SS) is a compact pharma cleanroom vacuum with recovery tank, filter chamber and wheel base in autoclavable stainless steel Type 316. A 5-stage filtration system with ULPA U15 and HEPA H14 makes it compatible with ISO Class 4 cleanrooms, and at only 60 dB(A) at 2 m it is built for daily dry recovery in contamination-controlled environments.

  • Stainless steel recovery tank, 15.1 L, with 8 L disposable bag
  • ULPA U15 (99.999 % at 0.12 µm) + HEPA H14 (99.995 % at 0.3 µm) — both included
  • 5-stage filtration — aerosol leak tested before delivery
  • Cleanroom compatible with ISO Class 4 (former Class 10)
  • Autoclavable stainless steel Type 316 (filter chamber, tank and wheel base)
  • Low noise: 60 dB(A) at 2 m
  • 3 optional Ø32 mm tool kits: Standard, ESD Safe, Autoclavable
Contact us Data sheet (PDF) Download factsheet (PDF)
Tiger-Vac CR-1000 (SS) cleanroom vacuum with stainless steel tank on four wheels
ULPA U15 — EN 1822 / IEST-RP-CC001
HEPA H14 — EN 1822 (MPPS) / IEST-RP-CC001
ISO Class 4 (ISO 14644-1)
Stainless steel Type 316 — autoclavable
CE — Machinery Directive 2006/42/EC

What is the Tiger-Vac CR-1000 (SS)?

The CR-1000 (SS) — where SS stands for stainless steel — is Tiger-Vac's compact cleanroom vacuum for dry recovery in pharma and other contamination-controlled environments. It is cleanroom compatible with ISO Class 4 (former Class 10) and runs on a 1 kW Thru-Flow motor.

Dust is collected in an 8-litre disposable bag inside a 15.1-litre recovery tank in stainless steel Type 316. The tank, filter chamber and wheel base are all stainless steel Type 316 and can be autoclaved. The vacuum sits on a 4-wheel dolly and is easy to move between rooms.

The 5-stage filtration system consists of the disposable bag, a PTFE laminated main cloth filter, a safety filter, a HEPA H14 filter (99.995 % at 0.3 µm) and a ULPA U15 exhaust filter (99.999 % at 0.12 µm). All filters are included, and every unit is aerosol leak tested at Tiger-Vac before leaving the factory. Available in two versions: 111989 without and 111990 with a ULPA filter protector housing.

Important use restriction: The CR-1000 (SS) is for dry recovery only. It must not be used for liquids or wet material. If potent compounds must be collected in a sealed single-use container, the sister model CR-1000 (CV) is the right choice.
PTFE laminated main cloth filter for Tiger-Vac CR-1000 (SS)
PTFE laminated main cloth filter (included) — one of the five filtration stages of the CR-1000 (SS).
Airflow schematic for Tiger-Vac CR-1000 (SS) — 5-stage filtration
Airflow schematic of the CR-1000 (SS): air passes from the suction inlet through the disposable bag in the tank, up through the filter chamber and out through the ULPA U15 exhaust filter.

Technical specifications

ParameterValue
ConstructionStainless steel Type 316 (filter chamber, tank, wheel base)
Filter classULPA U15 (EN 1822 / IEST-RP-CC001)
ULPA filter efficiency99.999 % at 0.12 µm • 99.9995 % at 0.18 µm (MPPS)
HEPA filter efficiency (H14)99.995 % at 0.3 µm • H14 per EN 1822 (MPPS)
Filtration5-stage: disposable bag + PTFE laminated main cloth filter + safety filter + HEPA H14 + ULPA U15
Recovery tank15.1 L stainless steel with 8 L disposable bag
Cleanroom compatibilityISO Class 4 (ISO 14644-1)
Versions111989 without / 111990 with ULPA filter protector housing
Motor typeThru-Flow
Power1 kW / 1000 W
Voltage240 V, 50 Hz, single phase
Current4.3 A
Air flow163 m³/h
Vacuum pressure2,510 mmH₂O
Noise level60 dB(A) at 2 m
Suction inletØ38 mm
DimensionsH 74 × W 36 × L 53 cm
Weight (vacuum only)13 kg
Cord length10 m
Recovery typeDry only
AutoclavableYes — filter chamber, tank and wheel base (stainless steel Type 316)

CE marking (EU declaration of conformity for CR-1000, 26-04-2024) based on: EN 60204-1:2018 • EN 60335-1:2012 (A11:2014, A13:2017, A15:2021) • EN 60335-2-69:2012 • EN 60335-2-2:2010 (A11:2012, A1:2013) • EN 61000-6-2:2005 • EN 61000-6-4:2007 (A1:2011). Specifications are subject to change without notice.

Filters and accessories

The CR-1000 (SS) is supplied with ULPA U15 filter, HEPA H14 filter with safety filter, PTFE laminated main cloth filter and disposable bags. Three optional tool kits are available for Ø32 mm (1.25″).

HEPA H14 filter with safety filter for CR-1000 (SS)

HEPA H14 filter + safety filter

Part no. 212303 + 212303F2 • Included

PTFE laminated main cloth filter for CR-1000 (SS)

PTFE laminated main cloth filter

Part no. 212503T • Included

Image missing

Disposable bags, 8 L

Part no. 212500 (pack of 5) • Included

Standard tool kit for CR-1000 (SS)

Tool kit #1 — Standard

Part no. 323600 • Optional • Ø32 mm

ESD safe tool kit for CR-1000 (SS)

Tool kit #2 — ESD Safe

Part no. 323602 • Optional • Ø32 mm

Autoclavable tool kit for CR-1000 (SS)

Tool kit #3 — Autoclavable

Part no. 323604 • Optional • Ø32 mm

Questions and answers

Both share the same motor and 5-stage filtration with ULPA U15. The CR-1000 (SS) collects into a disposable bag inside a 15.1-litre stainless steel tank and is meant for daily dry recovery in cleanrooms. The CR-1000 (CV) instead collects into a sealed single-use canister that is disposed of closed, and is intended for potent compounds.
111989 is the version without a ULPA filter protector housing, 111990 is with it. The letter that follows gives the plug: B European, C UK, D Swiss and E Chinese. Otherwise the technical data are the same.
Both classes are defined in EN 1822 and tested using the MPPS method. The HEPA filter in the CR-1000 (SS) has an efficiency of 99.995 % at 0.3 µm (H14), and the ULPA filter 99.999 % at 0.12 µm and 99.9995 % at 0.18 µm (U15). Both are tested to IEST-RP-CC001, and every unit is aerosol leak tested before delivery.
No. The CR-1000 (SS) is for dry recovery of dust and powder only. Liquids and wet material must not be picked up.
The filter chamber, recovery tank and wheel base, all made of stainless steel Type 316.
Three optional kits for Ø32 mm (1.25″) with a 2.4 m hose: Kit #1 (part no. 323600) is standard plastic tools. Kit #2 (part no. 323602) is ESD safe with stainless steel wands. Kit #3 (part no. 323604) is autoclavable with EPDM hose, stainless steel wands and tools, and a silicone nozzle.

Is the Tiger-Vac CR-1000 (SS) the right model for you?

We advise on cleanroom vacuums for pharma and life science. Call or write — the advice is free and without obligation.