dustrap by Particulair DA · EN
Menu
ATEX zone 22H14 filter as standardManual filter shaker
Delfin Z22 ZFR EV AP 560 K4 dust collector for ATEX zone 22, grey body with blue motor head and filter lever
ATEX dust collector · Delfin

Z22 ZFR EV AP 560 K4

Dust collector for combustible dust in ATEX zone 22 areas.

A 4 kW dry-type dust collector with a star filter in antistatic polyester (ANT M) and an H14 absolute filter as standard. You clean the filter with a manual shaker while the machine is switched off.

3,500m³/hMax. air flow
370mmH₂OMax. negative pressure
Ø200mmSuction inlet
4kW400 V, 50 Hz
II 3D Ex h IIIC T80°C (int) / T135°C (ext) X Dc

Only for ATEX zone 22 areas and dust with a minimum ignition energy (MIE) above 3 mJ.

€9,927 List price excl. VAT, for business customers. Freight and installation not included.

Need less air? See the Z22 ZFR EV AP 560 K2 (2.2 kW, 2,500 m³/h).

Sources: Delfin manual Z22 ZFR EV AP 560 (EN), sections 2.4.1, 2.4.2, 4.1, 4.4 and 7.3.3; Delfin price list 2026, p. 120.

Before you choose

Is it right for your dust?

The manual sets clear limits. If your dust, process or area is on the “Not permitted” list, this machine is not the right choice.

Permitted

  • Suction and filtration in ATEX zone 22 classified areas
  • Combustible dust with a minimum ignition energy (MIE) above 3 mJ
  • Material that is no warmer than the ambient temperature
  • Filters chosen to suit the dust, based on its chemical and physical properties and safety data sheet

Not permitted

  • Use in zones 0, 1 and 2 (gas) or zones 20 and 21 (dust)
  • Dust with a minimum ignition energy (MIE) of 3 mJ or less
  • Self-igniting or exothermic dust, incandescent particles, oxidising dust and explosive substances
  • Flammable liquids, hybrid mixtures, liquids, or dust wetted with solvents
  • Connection to machinery that can generate ignition sources

Self-igniting or exothermic dust?For this type of dust, Delfin recommends the wet-type Inert version.

See the Inert version

Not sure about your dust?The MIE of many dusts is listed in BIA-Report 12/97. Or ask us before you choose.

Ask us

Source: Delfin manual Z22 ZFR EV AP 560 (EN), sections 2.4.2 "Meaning of the letter X", 4.1 "Intended use" and 4.3.1 "Operating cycle". Follow the manual for your machine.

How it works

Two filters. Four steps.

The air passes through two stages of filtration before it leaves the machine. Heavier material drops straight into the container.

1 Dusty air in, Ø200 2 Container100 l 3 Primaryfilter 4 Secondaryfilter, clean air

Simplified illustration, not to scale.

  1. 01Dusty air inThe extracted air enters the machine through the Ø200 mm suction inlet.
  2. 02Heavy material drops outThe heavier material falls straight into the 100 l container.
  3. 03Primary filterThe dusty air passes through the star filter, which captures the dust.
  4. 04Clean air outThe air passes the secondary filter and leaves through the clean air outlet.
Stage 1 · Primary filter
> 95%

Star filter in antistatic polyester ANT M, 50,000 cm².

Stage 2 · Secondary filter
> 99.95%

H14 absolute filter, standard on this model.

Clean the primary filter with the manual shaker, always with the machine switched off.Filter cleaning

Source: Delfin manual Z22 ZFR EV AP 560 (EN), sections 4.3.1 "Operating cycle", 4.4 "Technical features" and 7.3.3 "Filter cleaning system"; H14 filter as standard: Delfin price list 2026, p. 120.

Technical data

Specifications.

The K4 next to its smaller sibling, the K2. Same body, filter and ATEX marking. The K4 moves more air and pulls harder.

Technical data for Delfin Z22 ZFR EV AP 560 K2 and K4
ModelSmaller versionZ22 ZFR EV AP 560 K2This pageZ22 ZFR EV AP 560 K4
Performance
Max. air flow2,500 m³/h3,500 m³/h
Max. negative pressure210 mmH₂O370 mmH₂O
Suction inletØ200 mmØ200 mm
Power2.2 kW4 kW
Voltage, frequency400 V, 50 Hz400 V, 50 Hz
Current–7.6 A
Filtration
Primary filterStar filter, polyester ANT MStar filter, polyester ANT M
Filter surface50,000 cm²50,000 cm²
Filter diameterØ560 mmØ560 mm
Secondary filterH14, standardH14, standard
Filter cleaningManual shakerManual shaker
Machine
Container100 l100 l
Dimensions78 × 126 × 251 cm78 × 126 × 251 cm
Weight100 kg130 kg
Noise level72 dB(A)74 dB(A)
Protection ratingIP55IP55
ATEX
MarkingII 3D Ex h IIIC T80°C (int) / T135°C (ext) X DcII 3D Ex h IIIC T80°C (int) / T135°C (ext) X Dc
Permitted areaATEX zone 22ATEX zone 22
Item codeZ22ZFREVAP560K4-001Z22ZFREVAP560K4-001
Price
List price excl. VAT€9,927

Values from the Delfin manual Z22 ZFR EV AP 560 (EN), sections 2.4.1, 4.4 and 4.5. Where the price list, datasheet or Delfin's website differ, the manual applies. Weight, protection rating and H14 filter: Delfin price list 2026, p. 120. Current (K4): Delfin datasheet. Price: Delfin price list 2026, p. 120.

Ask about this model
ATEX marking

What the marking means.

Every part of the marking on the type plate tells you something. Here is what it means for this machine.

1II

Equipment group II: intended for use in surface industries.

23

Category 3: normal level of protection, suitable for use with an external zone 22.

3D

For explosive atmospheres caused by combustible dust.

4Ex h

Explosion protection for non-electrical equipment. For this machine, Delfin states protection by constructional safety of the filter unit.

5IIIC

Dust subgroup for conductive dust, for example metal powders.

6T80°C (int)

Maximum surface temperature inside the machine.

7T135°C (ext)

Maximum surface temperature on the outside of the machine.

8X

Special conditions for safe use apply. See below.

9Dc

Equipment protection level (EPL) for dust.

The X: special conditions

To avoid electrostatic charge, the manual sets three conditions.

  • Clean the outside only with a damp cloth or antistatic products.
  • Clean the machine regularly, so that dust layers never exceed 5 mm.
  • Connect the earthing clamp to a metal surface in contact with an earthing point.

EU declaration of conformity

Issued by Delfin S.r.l., Torino, for model Z22ZFREVAP560-001. Ambient temperature 0 to +40 °C.

  • ATEX Directive 2014/34/EU
  • Machinery Directive 2006/42/EC
  • Directives 2014/30/EU and 2014/35/EU
Standards applied (11)
  • EN 1127-1:2019
  • EN ISO 12100:2010
  • IEC EN 60079-0:2018
  • IEC EN 60079-31:2022
  • EN 80079-36:2016
  • EN 80079-37:2016
  • EN 17348:2022
  • EN 60335-1:2013
  • EN 60204-1:2018
  • IEC EN 60335-2-69:2012
  • IEC 60335-2-69:2021
Full declaration in the manual, section 2.6

Source: Delfin manual Z22 ZFR EV AP 560 (EN), sections 2.4.1 "Understanding the ATEX marking", 2.4.2 "Meaning of the letter X" and 2.6 "Copy of the declaration of conformity" (Rev.1, 25/03/2025).

Options and accessories

Make it fit your process.

Stainless steel versions, remote control, extraction arms and the right connection to your hoses.

Included as standardH14 absolute filter, 10 m²Earth grounding (MT)

Options, filters and accessories

What Delfin supplies for this model, with Delfin’s code. No prices: ask us for an offer.

Motor

ATEX motor II 3GD IIIC, 230/400 V, 60 Hz–

Filtration

Absolute HEPA filter, 10 m² (included)Absolute HEPA filter, 10 m² (included)H

Construction

AISI 304 stainless steel collection tankX
AISI 304 stainless steel tank and filter chamberXX
AISI 304 stainless steel filter chamber, collection tank, cover and frameXXX
Earth grounding (included)Earth grounding (included)MT

Control

24 V remote control (with electrical panel if not installed)24 V remote control (with electrical panel if not installed)LOC REM

Accessories

Flanged reduction for flex hose, Ø200/200SL.2632.0200
Flanged reduction for flex hose, Ø200/150SL.6882.0200
Flanged reduction for flex hose, Ø200/120SL.3775.0200
Flanged reduction for flex hose, Ø200/100SL.6883.0200
Flanged two-way branch, Ø200/150/150SL.2775.0200
Flanged two-way branch, Ø200/120/120SL.2692.0200
Flanged two-way branch, Ø200/100/100SL.3022.0200
Articulated extraction arm with earth grounding, Ø100/Ø100TA.0943.0000
Articulated extraction arm with earth grounding, Ø150/Ø150TA.0177.0000
Articulated extraction arm with earth grounding, Ø150/Ø200TA.1256.0000
Articulated extraction arm with earth grounding, Ø200/Ø200TA.0511.0000
Flanged branch for articulated arms, Ø200/100/100ESSL.2201.0200
Flanged branch for articulated arms, Ø200/150/150ESSL.4703.0200

Source: Delfin price list 2026, p. 120, 121; icons from Delfin.

Extraction arms

Articulated arms with earth grounding, 3,000 mm.

Extraction arms: arm diameter and filter chamber inlet
CodeArmInlet
TA.1256.0000Ø150Ø200
TA.0511.0000Ø200Ø200
TA.0177.0000Ø150Ø150

Two arms on one machine

2-way branch Ø200 to 2 × Ø150ESSL.4703.0200
2-way branch Ø200 to 2 × Ø100ESSL.2201.0200

Hose connections

Flanged iron fittings between the Ø200 inlet and a flexible hose.

Connection Ø200 to Ø200SL.2632.0200
Reduction Ø200 to Ø150SL.6882.0200
Reduction Ø200 to Ø120SL.3775.0200
Reduction Ø200 to Ø100SL.6883.0200
2-way branch Ø200 to 2 × Ø150SL.2775.0200
2-way branch Ø200 to 2 × Ø120SL.2692.0200
2-way branch Ø200 to 2 × Ø100SL.3022.0200

Hoses

Hose diameter and length affect airflow, conveying velocity and pressure loss. Select the hose based on the material, application and system requirements.

The machine reaches up to 370 mmH₂O, about 0.036 bar, which is within the rating of AIRDUC PUR 351 EC (MD). Check the inlet fit: the fit on the inlet spigot is not documented. Hose and accessories must be electrically continuous, so that static electricity from suction is led to earth.

Need a stainless version or two arms on one machine?

Ask about options

Sources: Delfin price list 2026, pp. 120 and 121 (standard equipment, options, arms and fittings). Hoses: NORRES data on our FlexCore pages (5 Oct 2026); hose recommendation: Particulair, 19 Oct 2026.

Service

Service at a glance.

The checks for this machine from the manual, by interval. We send service reminders based on the manufacturer's recommended maintenance intervals.

Every
8 h
  • Suction hose and accessories are intact
  • Fill level of the containerEmpty it at 3/4 of the capacity.
  • Electrical continuity to earth
Every
200 h
  • Wear of the anti-spark deflector
Every
1,000 h
  • Sealing gaskets
  • Electrical components
  • Screws and bolts
  • Filter is intact and not clogged
Every
12 months
  • Replace the primary filter and the H filterThe lifetime depends on use. Replace in any case every 12 months.

Source: Delfin manual Z22 ZFR EV AP 560 (EN), section 8.4.1 "Checks and inspections". Intervals apply under normal operating conditions. Maintenance by qualified and authorised personnel, see section 8.1.

Documents

Datasheet and documents.

For buyers, safety staff and the people who run the machine. We make our own datasheets and do not publish the manufacturers’ files.

Datasheet · EN

Particulair datasheet

Our own datasheet for this model, with the data from the manual and the price list.

In preparation
Checklist · EN

Service checklist

All checks with their intervals, with columns for date and initials. Keep it by the machine.

2 pages · 0.2 MBDownload ↓
Need information from the manual, the EU declaration of conformity or a filter certificate?Ask us

Datasheet and service checklist: Particulair, based on the Delfin manual Z22 ZFR EV AP 560 (EN, with EU declaration Rev.1 25/03/2025) and the Delfin price list 2026.

Other Particulair universes

Need help finding the right dust collector for your process?

We're ready to advise on selection and sizing.