Manual filter shaker
A lever is connected directly to the filter. Moving the lever up and down compresses the filter, so the material comes off its surface and falls into the container.
DA · EN
Easy to service. We remind you when it's time.
The machines are easy to service, so you can do it yourself. We send service reminders by email, based on the manufacturer's recommended maintenance intervals. You decide whether to accept the offer, with no service technician to pay for.
How the filter works
Illustrative animation, not to scale. The cleaning system differs between machines. Follow the manual for your machine.
Example from the Delfin ZFR EV AP 560 manual, section 8.4.1. Intervals apply under normal operating conditions and differ between models. Always follow the manual for your machine.
You do not have to remember when the filters and gaskets are due. We do, and we tell you in time.
We note the manufacturer's recommended intervals for filters and gaskets on your machine.
When it is time, we contact you automatically by email, so you are kept informed along the way.
You choose whether to accept the offer. You change the parts yourself, with no service technician to pay for.
Illustration of a filter with manual shaking. Not to scale.
On the Delfin machines a vacuum gauge on top of the machine shows the vacuum inside. It lets you follow how full the filter is, so you can plan maintenance before suction drops.
Source: Delfin manuals ZFR EV AP 560 and CUBE 20, section 7.3.3 "Filter cleaning system" and the description of the vacuum gauge. Machines from other manufacturers can show the filter state in a different way. Follow the manual for your machine.
The manual lists ten routine checks, each with a fixed interval. Choose an interval to see what is due.
Source: Delfin manuals ZFR EV AP 560 and CUBE 20 K2/K4 PN, section 8.4.1 "Checks and inspections". The intervals apply under normal operating conditions. Other models and brands can have other intervals. Follow the manual for your machine.
Get the list as a PDFThe solution to most problems is in this list. Choose what you notice, and check the causes from the top.
Check the hose and replace it if necessary.
Empty the container.
Clean the filter with the filter cleaning system, or replace it if necessary.
Check the seals and replace them if necessary.
Check the closing hooks, clamping screws, collection container and filter chamber.
Source: Delfin manuals ZFR EV AP 560 and CUBE 20 K2/K4 PN, section 9.2 "Troubleshooting". Problems with compressed air and the electronic board apply to models with automatic filter cleaning. Follow the manual for your machine.
How you clean the filter depends on the machine. The dust comes off the filter and falls into the container.
A lever is connected directly to the filter. Moving the lever up and down compresses the filter, so the material comes off its surface and falls into the container.
A pneumatic piston is connected directly to the filter. Its up and down movement compresses the filter, so the material comes off and falls into the container.
Each filter cartridge is cleaned at adjustable intervals by a high-pressure air jet. The jet shakes the cartridge and removes large amounts of material, so the filter is clean in a matter of seconds.
Source: Depureco dust collectors catalogue (EN), "Filter cleaning system". Delfin machines with a filter lever are shaken by hand with the machine switched off (Delfin manuals, section 7.3.3). Which system your machine has is shown on its product page.
Six rules from the manual to follow every time you service the machine.
Only service the machine when it is switched off. Disconnect the plug before you shake or change the filter.
After switching off, wait 10 minutes so the dust can settle before you empty the container.
The collected dust can be hazardous to health. Wear suitable personal protection, and a dust mask if the machine has an H filter.
Put a sign on the machine: "Caution! Machine undergoing maintenance". Keep unauthorised people out of the area.
Do not use naked flames or hot gases on or near the machine during maintenance.
Maintenance must be carried out by qualified and authorised personnel.
The personnel need specific training in explosion prevention and protection. Use only original filters and spare parts: they are part of the explosion protection, and non-original parts void the ATEX certification and the legal guarantee.
Source: Delfin manual ZFR EV AP 560 Z22, sections 7.3.3, 8.1, 8.3 and 8.4.1.1. Follow the manual for your machine.
Print it and keep it by the machine. Tick each check, write the date and your initials.
Tell us which machine you have. We send service reminders by email, based on the manufacturer's recommended maintenance intervals.
Short answers, each with the source it comes from. Didn't find your question?
Ask usThe lifetime of a filter depends on how the machine is used. On the Delfin machines, the primary filter and the H filter must in any case be replaced every 12 months. Other brands and models can have different intervals, so always follow the manual for your machine.
Source: Delfin manuals ZFR EV AP 560 and CUBE 20, section 8.4.1
Tell us which machine you have. We email you a service reminder with an offer, based on the manufacturer's recommended maintenance intervals. You decide whether to accept it. The work can be done by your own qualified staff, so you do not need to pay for a service visit. On ATEX machines, the staff must also be trained in explosion protection.
Source: Particulair service offer; Delfin manuals, section 8.1
On the Delfin machines, a vacuum gauge at the top of the machine shows the vacuum inside, so you can follow how saturated the filter is. If the gauge shows an irregular value while the machine is running and the suction inlet is free, switch the machine off and disconnect the plug. Then shake the filter with the filter lever, check the hose and accessories for blockages, and clean or replace the filter if necessary. Do not use the machine with a clogged filter. On ATEX machines, act promptly when the vacuum gauge signals a problem. Ignoring it can lead to overheating or ignition of combustible dust.
Source: Delfin manuals ZFR EV AP 560 and CUBE 20, sections 3, 7.2 and 7.3.3
On the Delfin machines, check the fill level every 8 hours of operation and empty the container when the material reaches 3/4 of its capacity. Before emptying, switch the machine off, disconnect the plug and wait 10 minutes so the dust can settle. Wear suitable protective equipment, and a dust mask if the machine has an H filter.
Source: Delfin manuals, sections 8.3, 8.4.1 and 8.4.1.1
Only if the person doing it is qualified and authorised. On ATEX machines, maintenance can itself become an ignition hazard, so the personnel also need specific training in explosion prevention and protection. Carry out maintenance only with the machine switched off, in a safe environment and at the intervals given in the manual. Maintenance work that is not described in the manual requires the manufacturer's prior approval.
Source: Delfin manual ZFR EV AP 560 Z22, sections 1.8 and 8.1
It depends on the machine and on the dust. If the dust is hazardous to health, the filter may only be changed by trained staff wearing the protective equipment your internal rules require. On ATEX machines, the person who changes the filter must be trained in explosion protection, and the training can be internal. The filter must be fitted so that it still conducts static electricity away. Always follow the manufacturer's manual. You do not need an external service technician.
Source: Particulair, 19 October 2026; manufacturers' manuals
On ATEX machines the original filters and spare parts are part of the explosion protection. Non-original parts void the ATEX certification and the legal guarantee, and the manufacturer accepts no liability for the machine if non-original spare parts are used. This applies to the Delfin ATEX machines. For other brands, follow the manual for your machine.
Source: Delfin manual ZFR EV AP 560 Z22, sections 8.1 and 8.5
Not on your own. The Delfin manuals say: to replace the motor, contact an authorised maintenance technician. If the motor is faulty or unusually noisy, contact technical support. Maintenance work that is not described in the manual may only be carried out with the manufacturer's prior approval, given in writing.
Source: Delfin manuals, sections 8.1, 8.4.1, 8.5 and 9.2
Vacuum solutions for pharma, cleanrooms and life science.
particulair.eu/life-scienceAccessories for vacuum cleaners in ATEX zones and food environments.
particulair.eu/vaceATEX and ACD vacuum cleaners for explosion-classified zones and combustible dust.
particulair.eu/ex-vacTechnical hoses for critical environments.
particulair.eu/flexcoreVibrators, air cannons and fluidisation that make powder flow out of silos and hoppers.
particulair.eu/flow-aid
We're ready to advise on selection and sizing.