EN 17348:2022 — Vacuum cleaners and dust collectors for explosive atmospheres
European product standard that defines the requirements for design, construction, testing and marking of industrial vacuum cleaners and dust collectors for use in potentially explosive atmospheres. A central contribution is the concept of internal ATEX zone, classifying the explosion hazard inside the collection system itself. The standard explicitly covers accessories: hoses, couplings, nozzles and filters are an integral part of the requirements and cannot be left unregulated. It also introduces the designation WT (Wet Type Dust Collector) for liquid-bath solutions. Harmonised under the ATEX Directive 2014/34/EU in March 2023 and under the Machinery Directive in August 2024. Before EN 17348 there was no specific product standard for these vacuum cleaners, and the standard is the first unambiguous basis for professional comparison.
Source: as on our Ex-Vac wiki
EN 1822-1:2019 — HEPA and ULPA filter classification
The European standard for high-efficiency air filters. Defines classes E10–E12 (EPA), H13–H14 (HEPA) and U15–U17 (ULPA) based on the filter element's minimum efficiency at MPPS (Most Penetrating Particle Size). H14 = 99.995 % efficiency at MPPS and is typically used as the final stage in ATEX vacuum cleaners when handling hazardous or carcinogenic dust. For ULPA U15 and above, the standard requires mandatory scan testing (PAO/DOP method) to verify filter integrity.
Source: as on our Ex-Vac wiki
ISO 29463 — High-efficiency filters (HEPA and ULPA)
International standard that supplements EN 1822 with additional requirements for classification and testing of HEPA and ULPA filters. ISO 29463-5 covers efficiency measurement at MPPS. Used as an alternative or supplement to EN 1822, particularly for international projects or for export to markets outside the EU. The classification nomenclature in the two standards differs, but the calculation methods are built on the same principles.
Source: as on our Ex-Vac wiki
EN 60079-10-2 — Classification of areas with explosive dust atmosphere
Defines the methodology for zone classification (Zone 20, 21 and 22) based on the likelihood and duration of an explosive dust atmosphere. Annex A gives indicative time intervals: Zone 20 > 1,000 hours/year, Zone 21 = 10–1,000 hours, Zone 22 < 10 hours. These figures are indicative and must not be read as absolute thresholds, but as an aid to risk assessment. Used together with the Danish Emergency Management Agency's order BEK 268/2010 in Denmark.
Source: as on our Ex-Vac wiki
EN 1127-1:2019 — Explosive atmospheres, prevention and protection against explosion
Fundamental standard for the prevention of and protection against explosions in industrial plants. Describes the three conditions for an explosion (combustible material, oxygen and ignition source — the fire/explosion triangle) and the methods used to eliminate them. Clause 6.4 covers ventilation and the risk that incorrect ventilation may spread combustible dust into new areas. Supplemented by the ATEX directives and the EN 60079 series and is one of the core references in an explosion protection document.
Source: as on our Ex-Vac wiki
EN ISO 80079-36 and -37 — Non-electrical equipment in explosive atmospheres
Defines construction requirements and test methods for non-electrical equipment (mechanical components, pumps, ventilation parts, accessories) in explosive atmospheres. The basis for the protection method Ex h: the construction is such that potential ignition sources cannot arise under normal operation. Electrical vacuum cleaners use Ex t (protection by enclosure) instead. Part -36 covers general requirements; part -37 covers specific protection types (Ex h c, Ex h b, Ex h k, etc.).
Source: as on our Ex-Vac wiki
EN 60079-32-1 — Electrostatic hazards, guidance
Guidance standard for managing electrostatic hazards in explosive atmospheres. Sets principal requirements and indicative limit values for grounding resistance — including the guideline limit of no more than 10⁶ Ω for metal components to be considered safely grounded in most combustible-dust applications. The standard covers material choice, grounding methods and control measures. This is the source of the indicative resistance values used for ATEX equipment and accessories.
Source: as on our Ex-Vac wiki
EN ISO 8031:2020 — Rubber and plastics hoses and hose assemblies, electrical properties
International standard for the measurement and documentation of electrical properties of hoses and hose assemblies. Defines the categories antistatic (typically < 10⁹ Ω) and electrically conductive (typically < 10⁶ Ω) together with end-to-end resistance test methods. Used as the test reference in EN 17348:2022, which requires documented resistance throughout the grounding chain from the vacuum cleaner's chassis bolt through the hose to the nozzle.
Source: as on our Ex-Vac wiki
EN 14034-1 to -4 — Determination of explosion characteristics of dust clouds
Standardised test apparatus and method for the measurement of dust explosion parameters in a 20-litre spherical test vessel. Part -1 covers maximum explosion pressure (Pmax), part -2 measures the explosion constant Kst and dKst, part -3 covers limiting oxygen concentration (LOC), and part -4 covers minimum explosible concentration (MEC). The results provide the basis for selecting the explosion-protection method (venting, suppression, isolation) and for grouping dust into the St classes St 1, St 2 and St 3.
Source: as on our Ex-Vac wiki
EN 13821 — Determination of minimum ignition energy (MIE) of dust/air mixtures
Defines the test method for determining the lowest energy that can ignite a dust/air mixture. MIE is typically expressed in millijoules (mJ). The result determines whether electrostatic discharges and ordinary ignition sources can trigger an explosion. For powders with MIE below 3 mJ, ESD protection and equipotential bonding are critical; for MIE below 0.1 mJ, inerting is normally required.
Source: as on our Ex-Vac wiki
EN 14491:2012 — Dust explosion venting protective systems
Describes the sizing and placement of venting systems that protect vessels and room structures against dust explosions. Built on Pmax and Kst values measured per EN 14034. Used for sizing vent panels on large dust collectors and silos. Smaller, sealed ATEX vacuum cleaners are typically built to withstand internal explosion without venting.
Source: as on our Ex-Vac wiki