DA · EN

Dust collector for explosive atmospheres.
The ATEX version of the DF 075 for combustible dust, including conductive dust (IIIC). Zone 20 inside, zone 22 outside.
II 1/3 D Ex h IIIC T140°C Da/DcZone 20 inside, zone 22 outside; Dust group IIIC, including conductive dust.
II 3D Ex h IIIC T140 DcWith the SP kit fitted (DF 075 SP ATEX, code A1900): category 3 inside and outside, so zone 22 also inside the machine.
€4,323 List price excl. VAT, for business customers. Freight and installation not included.
Source: Depureco EU declaration (facsimile) DF DEX II 1/3D, manual DF series (EN, rev. 01) and data sheet, as compiled in our model list (8 October 2026).
The limits as stated in the marking and the manufacturer’s documents. Your own zone classification decides.
Not sure about your zone or dust?Tell us what you know. We help you choose.
Ask usWhat the zones meanZones, dust groups and the minimum ignition temperature explained in short.
ATEX zones in the wikiSource: Depureco EU declaration (facsimile) DF DEX II 1/3D, manual DF series (EN, rev. 01) and data sheet, as compiled in our model list (8 October 2026).
How this machine filters the air and how the filter is kept clean.
Star filter, class M, antistatic polyester, 24,000 cm².
HEPA H13 option, 120,000 cm².
3 cartridges, class M, 90,000 cm², cleaned by reverse jet with compressed air.

Source: Depureco EU declaration (facsimile) DF DEX II 1/3D, manual DF series (EN, rev. 01) and data sheet, as compiled in our model list (8 October 2026).
The data for the DF 075 DEX 1/3D, with the source below. Air flow is the manufacturer’s maximum at the stated inlet.
| Model | This pageDF 075 DEX 1/3D | VariantDF 075 SP ATEX |
|---|---|---|
| Performance | ||
| Inlet and max. air flow | Ø70 mm → 300 m³/h, Ø100 mm → 600 m³/h, Ø120 mm → 800 m³/h | Ø70 mm → 300 m³/h, Ø100 mm → 600 m³/h, Ø120 mm → 800 m³/h |
| Max. negative pressure | 185 | 200 | 180 mmH₂O at Ø70 | Ø100 | Ø120 | 185 | 200 | 180 mmH₂O at Ø70 | Ø100 | Ø120 |
| Power | 0.75 kW, ATEX-certified 3D fan | 0.75 kW, ATEX-certified 3D fan |
| Voltage, frequency | 400 V, 50/60 Hz | 400 V, 50/60 Hz |
| Filtration | ||
| Primary filter | Star filter, class M, antistatic polyester, 24,000 cm² | 3 cartridges, class M, antistatic polyester, 90,000 cm² |
| HEPA filter | HEPA H13 option, 120,000 cm² | HEPA H13 option, 120,000 cm² |
| Filter cleaning | Manual shaker; PSC and SP available | Reverse jet with compressed air (SP kit fitted) |
| Machine | ||
| Container | Stainless steel container AISI 304, 65 l, 100 l as option | Stainless steel container AISI 304, 65 l, 100 l as option |
| Dimensions | 660 × 800 mm, height 1,630 mm | 660 × 800 mm, height 1,910 mm |
| Weight | 110 kg | 125 kg |
| Noise level | 65 dB(A) | 65 dB(A) |
| ATEX | ||
| Marking | II 1/3 D Ex h IIIC T140°C Da/Dc | II 3D Ex h IIIC T140 Dc |
| Item code | A1830 (catalogue) | A1900 (catalogue) |
| Price | ||
| List price excl. VAT | €4,323 | €6,608 |
Source: Depureco EU declaration (facsimile) DF DEX II 1/3D, manual DF series (EN, rev. 01) and data sheet, as compiled in our model list (8 October 2026). Where sources differ, the declaration and the manual apply. SP ATEX variant: Depureco price list 2026 (v. 1.1), p. 90. Price: Depureco price list 2026 (v. 1.1), p. 90.
Ask about this modelThe marking as stated in the manufacturer’s documents for this model.
II 1/3 D Ex h IIIC T140°C Da/Dc
II 3D Ex h IIIC T140 Dc according to Depureco’s price list 2026, p. 90. The EU declaration on this page covers II 1/3D only; we do not have a declaration for the SP ATEX variant.EU type examination TÜV CY 25 ATEX 0207499 X (TÜV Nord).
Source: Depureco EU declaration (facsimile) DF DEX II 1/3D, manual DF series (EN, rev. 01) and data sheet, as compiled in our model list (8 October 2026).
Options from the manufacturer, and the right hose for the inlet. No prices: ask us for an offer.
What Depureco supplies for this model, with Depureco’s item code. No prices: ask us for an offer.
Filtration
P12819PTFE ANTConstruction
GX100LTSILAccessories
P12300/70P12300/100P12300/120P12300/150P09697P10095P12358P12359P12335/70P12335/100P12335/120P12334/100P12788P12334P12370P11847P09577Source: Depureco price list 2026 (v. 1.1), p. 90; pictures from Depureco.
Match the hose diameter to the inlet. The hose must take the machine’s maximum vacuum at that diameter.
Need an option or a different version?
Ask about optionsSource: Depureco EU declaration (facsimile) DF DEX II 1/3D, manual DF series (EN, rev. 01) and data sheet, as compiled in our model list (8 October 2026).
We send service reminders based on the manufacturer’s recommended maintenance intervals. You decide whether to accept the offer.
For buyers, safety staff and the people who run the machine. We make our own datasheets and do not publish the manufacturers’ files.
Our own datasheet for this model, with the data from the manual and the price list.
All checks with their intervals, with columns for date and initials. Keep it by the machine.
Datasheet and service checklist: Particulair, based on the manufacturer’s documents.
Vacuum solutions for pharma, cleanrooms and life science.
particulair.eu/life-scienceAccessories for vacuum cleaners in ATEX zones and food environments.
particulair.eu/vaceATEX and ACD vacuum cleaners for explosion-classified zones and combustible dust.
particulair.eu/ex-vacTechnical hoses for critical environments.
particulair.eu/flexcoreVibrators, air cannons and fluidisation that make powder flow out of silos and hoppers.
particulair.eu/flow-aid
We're ready to advise on selection and sizing.