DA · EN
The Delfin ZFR EV 420 K07 1/3D is a compact, mobile dust collector for airborne combustible dust. It stands in zone 22, the filter chamber is approved for zone 20, and an H14 absolute filter is fitted as standard. Available in AISI 304 stainless steel all round.
We normally respond within one business day.
AI-generatedZFR EV 420 K07 1/3D in the stainless steel version (XXX) with a Ø100 mm extraction arm.
In pharma and biotech, a mobile dust collector has to do more than collect dust. Three things come up in almost every project.
The room is zone 22, and the dust inside the machine is a zone of its own. The machine must be approved for both.
The collector stands in the production room. Whatever passes the filters is blown back into the same room, so the last filter has to be right.
Quality assurance wants documentation on filter cleaning, containment, filter testing and standards before the machine is put into use.
What makes the difference when the extraction has to be approved and used every day.
The machine may stand in zone 22, and the filter chamber is approved for zone 20. Marking: II 1/3D Ex h IIIC T100°C (int) / T135°C (ext) Da/Dc.
The 10 m² absolute filter is H14 with 99.995% efficiency by the MPPS method. It sits after the main filter (polyester, class L), so the air is filtered twice before it returns to the room.
The standard version is painted steel. The XXX version has filter chamber, container, lid and frame in AISI 304 stainless steel and is easily wiped clean with a damp cloth.
The main filter is easily shaken with a lever while the machine is switched off. No compressed air and no controls. A vacuum gauge on top shows when it is time.
1,000 m³/h, a Ø100 mm inlet and a 45-litre container that is easily removed and emptied. It rolls easily on wheels with a push handle to wherever the work is.
EU declaration of conformity listing 11 standards, incl. EN 17348, EN 60079-0 and EN 60335-2-69, plus the manual and our own data sheet. We answer QA’s questions in writing, with sources.
Same machine, same filters and the same ATEX approval. The difference is the material.


Answers for everyone who has to approve the purchase.
Simple to use: switch on, collect, switch off, shake the filter, empty the container. No compressed air, no controls, and it moves easily on wheels.
H14 filter with 99.995% (MPPS), stainless steel and an EU declaration of conformity that lists the standards. We answer in writing, with sources.
Marked for zone 22, filter chamber for zone 20. For dust with a minimum ignition energy (MIE) of at least 3 mJ. Earthing included.
A compact machine for 400 V. One contact from the first question to delivery. We help you commission the machine, train your staff in its use and servicing, and remind you when the filters are due.
Wherever powder is poured, weighed, blended or pressed, fine dust rises into the air. The extraction arm captures it at the source, before it spreads through the room and settles on equipment and people.

When raw materials and excipients are weighed out, the arm sits above the scale and captures the dust before it reaches the operator.

When the granulator and blender are filled and emptied, it captures the dust at the opening where it arises.

At the tablet press and capsule filler, it captures the dust from feeding and discharge, keeping the room clean between batches.
The paperwork decides.
A typical pharma project
A pharmaceutical manufacturer in Denmark was looking for mobile extraction for its production. First they looked at a large dust collector with automatic filter cleaning, but the price spoke against it. When the requirement for automatic cleaning was dropped, the ZFR EV 420 K07 1/3D in stainless steel was the best fit: zone 20 inside, zone 22 outside, H14 filter and a Ø100 mm extraction arm.
Along the way, quality assurance asked the important questions. How is the dust contained when the filter is cleaned? Can the HEPA filter be tested? Which standards is the machine built to? Fortunately, that is pharma: the machine does not just have to work, it has to be documented.
Short answers. If you want the long answer, call us.
A vacuum cleaner removes dust that has already settled on floors and machines. A dust collector captures airborne dust at the source, before it spreads. The ZFR EV 420 K07 1/3D is a dust collector: the extraction arm sits at the process and captures the dust while you work.
The machine may stand in zone 22, and the filter chamber is approved for zone 20. It may not stand in zone 20 or 21, and it is not for gas (zones 0, 1 and 2). If you need a model for dust zone 21 or gas zone 1, see the Tiger-Vac CD-1200 EX for zones 1/21. Your own zone classification decides. We are happy to help you read it.
Combustible dust with a minimum ignition energy (MIE) of at least 3 mJ. Not self-igniting or oxidising dust, explosive substances or dust wetted with solvents.
With a lever that easily shakes the main filter. This is done with the machine switched off and the plug pulled. The vacuum gauge on top shows when the filter starts to clog.
The HEPA filter must be replaced once a year. The main filter is replaced as needed, normally also once a year.
The EU declaration of conformity, the manual and our own data sheet. The declaration lists 11 standards, incl. EN 17348, EN 60079-0, EN 60079-31 and EN 60335-2-69. If your QA needs more, ask us.
400 V, 50 Hz three-phase power. If the machine stands in zone 22, the plug must be ATEX-approved; a standard plug may only be used outside the zone. The earthing clamp is attached to an earthed metal point.
We give you the current delivery time when you ask. The stainless steel version is made to order.
AI-generatedCall or write. Tell us which dust you handle, which zone the machine will stand in and what your QA needs. We will get back to you within one business day.
For zone 22, Delfin makes larger ZFR EV AP 560 models and the CUBE 20 with automatic filter cleaning during suction. Outside ATEX zones, the ZFR EV AP PN 560 has cartridge filters that are cleaned automatically with compressed air during suction. We help you choose by dust, process and zone.
We're ready to advise on selection and sizing.
Vacuum solutions for pharma, cleanrooms and life science.
particulair.eu/life-scienceAccessories for vacuum cleaners in ATEX zones and food environments.
particulair.eu/vaceATEX and ACD vacuum cleaners for explosion-classified zones and combustible dust.
particulair.eu/ex-vacTechnical hoses for critical environments.
particulair.eu/flexcoreVibrators, air cannons and fluidisation that make powder flow out of silos and hoppers.
particulair.eu/flow-aid