dustrap by Particulair DA · EN
Menu
Pharma and biotech · ATEX zone 22

Mobile ATEX extraction for pharma.
With the paperwork in order.

The Delfin ZFR EV 420 K07 1/3D is a compact, mobile dust collector for airborne combustible dust. It stands in zone 22, the filter chamber is approved for zone 20, and an H14 absolute filter is fitted as standard. Available in AISI 304 stainless steel all round.

  • Zone 22 outside, zone 20 inside
  • H14 absolute filter of 10 m² as standard
  • AISI 304 stainless steel: filter chamber, container, lid and frame
  • EU declaration of conformity listing 11 standards, incl. EN 17348

We normally respond within one business day.

1,000 m³/hDelfin ZFR EV 420 K07 1/3D in stainless steel with an extraction arm in a cleanroomAI-generated

ZFR EV 420 K07 1/3D in the stainless steel version (XXX) with a Ø100 mm extraction arm.

  • Zone 22 outside
  • Zone 20 inside
  • H14 absolute filter, 99.995% (MPPS)
  • AISI 304 stainless steel
  • 1,000 m³/h
  • Ø100 mm inlet
  • 45 l container
  • Manual filter cleaning, no compressed air
  • EN 17348
  • 400 V, 0.75 kW
  • We normally respond within one business day

When QA has to approve the extraction

In pharma and biotech, a mobile dust collector has to do more than collect dust. Three things come up in almost every project.

01

The zone is classified

The room is zone 22, and the dust inside the machine is a zone of its own. The machine must be approved for both.

02

The air goes back into the room

The collector stands in the production room. Whatever passes the filters is blown back into the same room, so the last filter has to be right.

03

Everything must be validated

Quality assurance wants documentation on filter cleaning, containment, filter testing and standards before the machine is put into use.

Six reasons to choose the ZFR EV 420 K07 1/3D

What makes the difference when the extraction has to be approved and used every day.

01

Approved inside and out

The machine may stand in zone 22, and the filter chamber is approved for zone 20. Marking: II 1/3D Ex h IIIC T100°C (int) / T135°C (ext) Da/Dc.

02

H14 as standard

The 10 m² absolute filter is H14 with 99.995% efficiency by the MPPS method. It sits after the main filter (polyester, class L), so the air is filtered twice before it returns to the room.

03

Stainless steel where it counts

The standard version is painted steel. The XXX version has filter chamber, container, lid and frame in AISI 304 stainless steel and is easily wiped clean with a damp cloth.

04

Filter cleaning without compressed air

The main filter is easily shaken with a lever while the machine is switched off. No compressed air and no controls. A vacuum gauge on top shows when it is time.

05

Small and mobile

1,000 m³/h, a Ø100 mm inlet and a 45-litre container that is easily removed and emptied. It rolls easily on wheels with a push handle to wherever the work is.

06

Documents for validation

EU declaration of conformity listing 11 standards, incl. EN 17348, EN 60079-0 and EN 60335-2-69, plus the manual and our own data sheet. We answer QA’s questions in writing, with sources.

Two versions

Same machine, same filters and the same ATEX approval. The difference is the material.

Delfin ZFR EV 420 K07 1/3D in painted steel
Standard · Z22ZFREV420-001Painted steelH14 absolute filter and earthing included. For production where stainless steel is not required.
See technical data →
Delfin ZFR EV 420 K07 1/3D in AISI 304 stainless steel
Option · XXXAISI 304 stainless steelFilter chamber, container, lid and frame in stainless steel. Made to order. Delfin also offers X (container) and XX (container and filter chamber) in stainless steel.
With Ø100 mm extraction arm from EUR 13,003 excl. VAT.
Ask about delivery time →

What does it give you?

Answers for everyone who has to approve the purchase.

Production

Simple to use: switch on, collect, switch off, shake the filter, empty the container. No compressed air, no controls, and it moves easily on wheels.

QA and validation

H14 filter with 99.995% (MPPS), stainless steel and an EU declaration of conformity that lists the standards. We answer in writing, with sources.

Safety and ATEX

Marked for zone 22, filter chamber for zone 20. For dust with a minimum ignition energy (MIE) of at least 3 mJ. Earthing included.

Purchasing and projects

A compact machine for 400 V. One contact from the first question to delivery. We help you commission the machine, train your staff in its use and servicing, and remind you when the filters are due.

For powder processes in GMP production

Wherever powder is poured, weighed, blended or pressed, fine dust rises into the air. The extraction arm captures it at the source, before it spreads through the room and settles on equipment and people.

01

Weighing and dispensing

When raw materials and excipients are weighed out, the arm sits above the scale and captures the dust before it reaches the operator.

02

Granulation and blending

When the granulator and blender are filled and emptied, it captures the dust at the opening where it arises.

03

Tablet pressing and capsule filling

At the tablet press and capsule filler, it captures the dust from feeding and discharge, keeping the room clean between batches.

From our work

The paperwork decides.

A typical pharma project

A pharmaceutical manufacturer in Denmark was looking for mobile extraction for its production. First they looked at a large dust collector with automatic filter cleaning, but the price spoke against it. When the requirement for automatic cleaning was dropped, the ZFR EV 420 K07 1/3D in stainless steel was the best fit: zone 20 inside, zone 22 outside, H14 filter and a Ø100 mm extraction arm.

Along the way, quality assurance asked the important questions. How is the dust contained when the filter is cleaned? Can the HEPA filter be tested? Which standards is the machine built to? Fortunately, that is pharma: the machine does not just have to work, it has to be documented.

Zone 20inside, zone 22 outside
H1499.995% by the MPPS method
Ø100 mminlet and extraction arm
3 questionsfrom QA: containment, filter testing and standards

What you usually ask

Short answers. If you want the long answer, call us.

What is the difference between a dust collector and a vacuum cleaner?

A vacuum cleaner removes dust that has already settled on floors and machines. A dust collector captures airborne dust at the source, before it spreads. The ZFR EV 420 K07 1/3D is a dust collector: the extraction arm sits at the process and captures the dust while you work.

May it stand in our zone?

The machine may stand in zone 22, and the filter chamber is approved for zone 20. It may not stand in zone 20 or 21, and it is not for gas (zones 0, 1 and 2). If you need a model for dust zone 21 or gas zone 1, see the Tiger-Vac CD-1200 EX for zones 1/21. Your own zone classification decides. We are happy to help you read it.

Which dust may it collect?

Combustible dust with a minimum ignition energy (MIE) of at least 3 mJ. Not self-igniting or oxidising dust, explosive substances or dust wetted with solvents.

How is the filter cleaned?

With a lever that easily shakes the main filter. This is done with the machine switched off and the plug pulled. The vacuum gauge on top shows when the filter starts to clog.

How often are the filters replaced?

The HEPA filter must be replaced once a year. The main filter is replaced as needed, normally also once a year.

Which documents do we get?

The EU declaration of conformity, the manual and our own data sheet. The declaration lists 11 standards, incl. EN 17348, EN 60079-0, EN 60079-31 and EN 60335-2-69. If your QA needs more, ask us.

What does it need on site?

400 V, 50 Hz three-phase power. If the machine stands in zone 22, the plug must be ATEX-approved; a standard plug may only be used outside the zone. The earthing clamp is attached to an earthed metal point.

What is the delivery time?

We give you the current delivery time when you ask. The stainless steel version is made to order.

Adviser and customer at a conveyor in a production plantAI-generated

Let us look at your task.

Call or write. Tell us which dust you handle, which zone the machine will stand in and what your QA needs. We will get back to you within one business day.

More solutions from Particulair

Need more air or automatic filter cleaning?

For zone 22, Delfin makes larger ZFR EV AP 560 models and the CUBE 20 with automatic filter cleaning during suction. Outside ATEX zones, the ZFR EV AP PN 560 has cartridge filters that are cleaned automatically with compressed air during suction. We help you choose by dust, process and zone.

Portrait of a technical adviser at Particulair

Need help finding the right dust collector for your process?

We're ready to advise on selection and sizing.

Other Particulair universes