ATEX zones
Areas where an explosive dust atmosphere can occur are classified as zone 20, 21 or 22; for gas as zone 0, 1 or 2. The employer classifies the zones, and the machine's marking must cover the zone it works in.
DA · EN
Gas group, temperature class and flash point for 44 ICH Q3C solvents, and what they mean for the choice of dust collector.
3 short parts.
Part1The listFlash point, temperature class and gas group.↓ Part2Diluted in waterAlcohol in water is still flammable.↓ Part3Related entriesMore on the same topic.↓Gas group and temperature class decide whether a machine may be used where there is vapour.
If solvents are used at the machine, the dust collector must be marked for gas. Only Tiger-Vac's CD EX models are: externally Ex db h IIB T4 Gb, so they may stand in zones 1 and 2, and internally Ex h IIC T6 Ga. IIB also covers IIA, and T4 means a surface temperature of at most 135 °C. Delfin's dust collectors are marked for dust only and are not used where there is vapour.
All substances in the table for which GESTIS gives a gas group fall within IIB T4. For 2-butanol, DMSO, DMAc and 2-MTHF, GESTIS gives no group. We check those in the supplier's safety data sheet before we say yes.
Models for zones 1 and 21| Substance | ICH class | Flash point °C | Temperature class | Gas group |
|---|---|---|---|---|
| Acetone | 3 | <−20 | T1 | IIA |
| Acetic acid | 3 | 38.5 | T1 | IIA |
| Anisole | 3 | 41 | T1 | IIB |
| 1-Butanol | 3 | 35 | T2 | IIB |
| 2-Butanol | 3 | 23 | T2 | not given |
| Butyl acetate | 3 | 27 | T2 | IIA |
| MTBE | 3 | −28 | T2 | IIA |
| DMSO | 3 | 88 | T3 | not given |
| Ethanol | 3 | 12 | T2 | IIB |
| Ethyl acetate | 3 | −4 | T1 | IIA |
| Diethyl ether | 3 | −40 | T4 | IIB |
| Ethyl formate | 3 | −20 | T2 | IIA |
| Formic acid | 3 | 45 | T1 | IIA |
| Heptane | 3 | −7 | T3 | IIA |
| Isobutyl acetate | 3 | 18 | T2 | IIA |
| Isopropyl acetate | 3 | 1.5 | T2 | IIA |
| Methyl acetate | 3 | −13 | T1 | IIA |
| 3-Methyl-1-butanol | 3 | ca. 42 | T2 | IIA |
| Butanone (MEK) | 3 | −7.5 | T1 | IIA |
| 2-Methyl-1-propanol | 3 | 27 | T2 | IIA |
| Pentane | 3 | −48 | T3 | IIA |
| 1-Pentanol | 3 | 42.5 | T2 | IIA |
| 1-Propanol | 3 | 22 | T2 | IIA–IIB |
| 2-Propanol (isopropanol) | 3 | 12 | T2 | not given; MESG 0.97 mm (IIA) |
| Propyl acetate | 3 | 10 | T1 | IIA |
| Triethylamine | 3 | −7 | T3 | IIA |
| tert-Butanol | R8 | 11 | T1 | IIA |
| 2-Methyltetrahydrofuran (2-MTHF) | R8 | −11 | T3 | not given |
| Acetonitrile | 2 | 2 | T1 | IIA |
| Cyclohexane | 2 | −18 | T3 | IIA |
| 1,2-Dimethoxyethane | 2 | −2 | T4 | IIB |
| DMAc | 2 | 66 | T2 | not given |
| DMF | 2 | 58 | T2 | IIA |
| 1,4-Dioxane | 2 | 11 | T2 | IIB |
| Hexane | 2 | <−20 | T3 | IIA |
| Methanol | 2 | 9 | T2 | IIA |
| Methylcyclohexane | 2 | −4 | T3 | IIA |
| MIBK | 2 | 14 | T1 | IIA |
| NMP | 2 | 86 | T3 | IIA |
| Pyridine | 2 | 17 | T1 | IIA |
| THF | 2 | −20 | T3 | IIB |
| Toluene | 2 | 6 | T1 | IIA |
| Xylene (mixed isomers) | 2 | 25 | T1 | IIA |
| Cumene | 2 | 31 | T2 | IIA |
Sources: ICH Q3C (FDA, "Q3C — Tables and List", rev. 4, 2018, and Q3C(R8)); substance data from the GESTIS Substance Database (IFA/DGUV), gestis.dguv.de, looked up 21-11-2026. Cyclopentyl methyl ether from Q3C(R8) is not in GESTIS and is not included.
70 % ethanol has a flash point of 21 °C and pure ethanol 12 °C, so both can ignite at room temperature.
Even 10 % ethanol, isopropanol or methanol can give flammable vapour at 41–54 °C, for example in a fluid bed dryer. A particle filter does not remove the vapour. If odour and vapour must be removed, the CD-595 EX HEPA VOC has activated carbon. The zone at the source is set out in your explosion protection document.
CD-595 EX HEPA VOCSend us what you know, and we take it from there.
The wiki gives general explanations. Always check the marking and the manual of your machine.
Vacuum solutions for pharma, cleanrooms and life science.
particulair.eu/life-scienceAccessories for vacuum cleaners in ATEX zones and food environments.
particulair.eu/vaceATEX and ACD vacuum cleaners for explosion-classified zones and combustible dust.
particulair.eu/ex-vacTechnical hoses for critical environments.
particulair.eu/flexcoreVibrators, air cannons and fluidisation that make powder flow out of silos and hoppers.
particulair.eu/flow-aid
We're ready to advise on selection and sizing.